|Table of Contents|

Elasto-Plastic Analysis of Concrete-Filled Circular Steel Tube Stub Columns After Constant High Temperature(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2006年01期
Page:
34-38
Research Field:
Publishing date:
2006-03-20

Info

Title:
Elasto-Plastic Analysis of Concrete-Filled Circular Steel Tube Stub Columns After Constant High Temperature
Author(s):
DING Fa-xing YU Zhi-wu
School of Civil Engineering and Architecture, Central South University, Changsha 410075, Hunan, China
Keywords:
concrete-filled steel tube stress-strain relationship elasto-plastic analysis constant high temperature
PACS:
TU528.59
DOI:
-
Abstract:
Based on the research of the mechanical properties of concrete at uniaxial compression and steel at uniaxial tension after constant high temperature, the axisymmetric triaxial compressive stress-strain relationships of concrete and multiaxial stress-strain relationships of steel after constant high temperatures were suggested. Based on continuum mechanics, the mechanical model of concentric cylinders of circular steel tube with concrete core of entire section loaded after constant high temperature was determined. Applying elasto-plastic analysis method, theoretical calculation formulas for composite elastic modulus and composite stress-strain relationships of concrete-filled circular steel tube(CFST)stub columns were proposed and a FORTRAN program was developed, and the load-axial strain relationships of CFST stub columns after constant high temperatures were analyzed. The analysis results are in reasonable agreement with the experiment ones.

References:

[1] 余志武,丁发兴,罗建平.高温后不同类型混凝土力学性能试验研究[J].安全与环境学报,2005,6(5):1-6. YU Zhi-wu,DING Fa-xing,LUO Jian-ping.Experimental Research on Mechanical Properties of Different Type of Concrete After High Temperature[J].Journal of Safety and Environment,2005,6(5):1-6.
[2]郭军庆,王雪韵,雷自学,等.加芯混凝土框架柱轴压比限值试验研究[J].建筑科学与工程学报,2005,22(4):45-49. GUO Jun-qing,WANG Xue-yun,LEI Zi-xue,et al.Experimental Research on Limit Value of Axial Compression Ratio for Concrete Frame Columns with Central Reinforcement[J].Journal of Architecture and Civil Engineering,2005,22(4):45-49.
[3]YU Z W,DING F X,WEN H L.Experimental Research on the Mechanical Properties of Steel After High Temperature[C]//SHEN Z Y,LI G Q,CHAN S L.Advances in Steel Structures.Shanghai:Shanghai Science and Technology Press,2005:1 071-1 076.
[4]余志武,丁发兴,林 松.高温后钢管高性能混凝土轴压短柱力学性能研究[J].铁道学报,2003,25(4):71-79. YU Zhi-wu,DING Fa-xing,LIN Song.Researches on Mechanical Behavior of High-Performance Concrete Filled Tubular Steel Stub Columns After High Temperature[J].Journal of the China Railway Society,2003,25(4):71-79.
[5]杨 华,韩林海.高温作用后圆钢管混凝土轴压力学性能研究[J].工业建筑,2001,31(11):50-54. YANG Hua,HAN Lin-hai.Mechanical Behavior of Concrete Filled Circular Steel Tublar Stub Columns After High Temperatures[J].Industrial Construction,2001,31(11):50-54.
[6]余志武,唐国庆,丁发兴.三面受火钢筋混凝土梁温度场非线性分析[J].建筑科学与工程学报,2005,22(4):11-14. YU Zhi-wu,TANG Guo-qing,DING Fa-xing.Nonlinear Analysis of Temperature Field of Reinforced Concrete Beam with Three Surfaces Exposing to Fire[J].Journal of Architecture and Civil Engineering,2005,22(4):11-14.
[7]丁发兴,余志武.钢管混凝土基本力学性能研究:理论分析[J].工程力学,2005,22(1):173-181. DING Fa-xing,YU Zhi-wu.Theoretical Analysis of Mechanical Properties of Concrete-Filled Tublar Steel Stub Columns[J].Engineering Mechanics,2005,22(1):173-181.
[8]余志武,丁发兴.混凝土受压力学性能统一计算方法[J].建筑结构学报,2003,24(4):41-46. YU Zhi-wu,DING Fa-xing.Unified Calculation Method of Compressive Mechanical Properties of Concrete[J].Journal of Building Structures,2003,24(4):41-46.

Memo

Memo:
-
Last Update: 2006-03-20