|Table of Contents|

Carbonation Model and Structural Durability Design for Recycled Concrete(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2008年03期
Page:
66-72
Research Field:
Publishing date:
2008-09-20

Info

Title:
Carbonation Model and Structural Durability Design for Recycled Concrete
Author(s):
XIAO Jian-zhuang LEI Bin
Department of Architectural Engineering, Tongji University, Shanghai 200092, China
Keywords:
recycled concrete carbonation model structural durability design reliability ana-lysis minimal thickness of recycled concrete cover of reinforcement
PACS:
TU528.57
DOI:
-
Abstract:
Based on the investigation of available achievements on carbonation of recycled concrete and concrete carbonation test data at home and abroad, the calculation model of recycled concrete carbonation depth was established and the limit state method and the partial safety factor method for recycled concrete structures were put forward. The reliability analysis of service life for recycled concrete beams was undertaken. Results show that the increase of compressive strength grades of recycled concrete and thickness of recycled concrete cover can improve the durability life of recycled concrete structures remarkably; while stress state of recycled concrete and the placement of reinforcing bars will have significant effects on the durability life of recycled concrete structures. Comprehensively considering the effect extent of carbonation-initiated corrosion of reinforcement on the functionality of recycled concrete structures and the different stress states of recycled concrete elements, the minimal thickness of recycled concrete cover of reinforcement in recycled concrete elements was proposed in Shanghai area.

References:

[1] DHIR R K,LIMBACHIYA M C.Suitability of Re-cycled Aggregate for Use in BS 5328 Designated Mixes[C]//ICE.Proceedings of the Institution of Civil Engineers.New York:ICE,1999:257-274.
[2]LIMBACHIYA M C,LEELAWAT T,DHIR R K.Use of Recycled Concrete Aggregate in High-strength Concrete[J].Materials and Structures,2000,33:574-580.
[3]FUNG W K.Durability of Concrete Using Recycled Aggregates[C]//SCCT.SCCT Annual Concrete Seminar.Hong Kong:SCCT,2005:101-129.
[4]陈云钢.界面改性剂对再生混凝土性能改善效果的初步研究[D].上海: 同济大学,2006.CHEN Yun-gang.Preliminary Study on Performance-improving Effect of the Interface-zone in Recycled Concrete with the Interface-zone Modifying Agent[D].Shanghai:Tongji University,2006.
[5]XIAO Jian-zhuang,LEI Bin.On the Carbonation Behavior of Recycled Aggregate Concrete[C]//Tongji University.Proceedings of the International Sympo-sium on Innovation & Sustainability of Structures in Civil Engineering.Shanghai:Tongji University Press,2007:897-904.
[6]OTSUKI N,MIYAZATO S,YODSUDJAI W.Influence of Recycled Aggregate on Interfacial Transition Zone Strength Chloride Penetration and Carbonation[J].Journal of Materials in Civil Engineering,2003,15(5):443-451.
[7]崔正龙,杨力辉,大芳賀義喜,等.再生混凝土耐久性的试验研究(Ⅱ.再生混凝土的中性化试验)[J].科学技术与工程,2006,6(21):3516-3519.CUI Zheng-long,YANG Li-hui,OHAGA Y,et al.Durability Test Investigation on the Recycled Aggregate Concrete(Part 2 Neutralization Test on Recycled Aggregate Concrete)[J].Science Technology and Engineering,2006,6(21):3516-3519.
[8]KATZ A.Properties of Concrete Made with Recycled Aggregate from Partially Hydrated Old Concrete[J].Cement and Concrete Research,2003,33(5):703-711.
[9]TAMURA H,NISHIO A,OHASHI J,et al.High Quality Recycled Aggregate Concrete(HiRCA)Processed by Decompression and Rapid Release[C]//MALHOTRA V M.Fifth CANMET/ACI Inter-national Conforence on Recent Advances in Concrete Technology.Singapore:ASI,2001:491-502.
[10]牛荻涛.混凝土结构耐久性与寿命预测[M].北京:科学出版社,2003.NIU Di-tao.Durability and Life Forecast of Re-inforced Concrete Structure[M].Beijing:Science Press,2003.
[11]张 誉,蒋利学.基于碳化机理的混凝土碳化深度实用数学模型[J].工业建筑,1998,28(1):16-19.ZHANG Yu,JIANG Li-xue.A Practical Mathemat-ical Model of Concrete Carbonation Depth Based on the Mechanism[J].Industrial Construction,1998,28(1):16-19.
[12]GB 50010-2002,混凝土结构设计规范[S].GB 50010-2002,Code for Design of Concrete Structures[S].
[13]牛荻涛,董振平,浦聿修.预测混凝土碳化深度的随机模型[J].工业建筑,1999,29(9):41-45.NIU Di-tao,DONG Zhen-ping,PU Yu-xiu.Random Model of Predicting the Carbonated Concrete Depth[J].Industrial Construction,1999,29(9):41-45.
[14]CCES 01-2004,混凝土结构耐久性设计与施工指南[S].CCES 01-2004,Guidelines for the Durability Design and Construction of Concrete Structures[S].
[15]GB 50068-2001,建筑结构可靠度设计统一标准[S].GB 50068-2001,Unified Standard for Reliability Design of Building Structures[S].
[16]SARJA A,VESIKARI E.Durability Design of Concrete Structures[M].London:E & FN Spon,1996:165.
[17]金伟良,朱平华.混凝土结构耐久性的修复性等级划分[J].建筑科学与工程学报,2005,22(1):64-70.JIN Wei-liang,ZHU Ping-hua.Restorability Class Partition for Durability of Concrete Structure[J].Journal of Architecture and Civil Engineering,2005,22(1):64-70.
[18]贺拴海,吕颖钊.考虑材料耐久性的在役混凝土结构可靠度研究[J].建筑科学与工程学报,2005,22(1):71-75.HE Shuan-hai,LU Ying-zhao.Reliability Research of Existing Reinforced Concrete Structures[J].Journal of Architecture and Civil Engineering,2005,22(1):71-75.
[19]李建波,林 皋,陈健云,等.混凝土损伤演化的随机力学参数细观数值影响分析[J].建筑科学与工程学报,2007,24(3):7-12.LI Jian-bo,LIN Gao,CHEN Jian-yun,et al.Mesoscopic Numerical Influence Analysis of Random Mechanical Parameter of Concrete Damage Evolution[J].Journal of Architecture and Civil Engineering,2007,24(3):7-12.

Memo

Memo:
-
Last Update: 2008-09-20