|Table of Contents|

Research and Improvement on Seismic Performance Evaluation Method of High-rise Building Structures(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2012年04期
Page:
32-37
Research Field:
Publishing date:

Info

Title:
Research and Improvement on Seismic Performance Evaluation Method of High-rise Building Structures
Author(s):
MA Kai-ze1 LIU Bo-quan1 YAN Hong-liang1 LIANG Xing-wen2
1. School of Civil Engineering, Chang'an University, Xi'an 710061, Shaanxi, China; 2. School of Civil Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, Shaanxi, China
Keywords:
high-rise building structure seismic performance evaluation method modal Pushover analysis method capacity spectrum method displacement response spectrum performance objective elastic-plastic analysis
PACS:
TU973
DOI:
-
Abstract:
In order to calculate the influence of high-order vibration modes for elastic-plastic analysis of high-rise buildings, based on modal Pushover analysis(MPA)method, the capacity spectrum theory was used to take the place of dynamic time-history analysis. Converting the acceleration response spectrum of current code into displacement response spectrum, the displacement response of equivalent single degree of freedom system(ESDOF)in each vibration mode could be calculated by capacity spectrum method. Then, the displacement response of multiple degree of freedom(MDOF)could be obtained too, and it was used to compare with the objective displacement of each performance level, judging whether the structure satisfied its performance objective requirements or not. The results show that the method is reasonable to reflect the requirements of the structure under design earthquake displacement.

References:

[1] WOLFGRAM C,ROTH D,WILSON P,et al.Earthquake Simulation Tests of Three One-tenth Scale Models[J].Publication SP,1985,84:347-373.
[2]FAJFAR P,FISCHINGER M.N2—A Method for Nonlinear Seismic Analysis of Regular Structures[C]//JAEPD.Proceedings of the 9th World Conference on Earthquake Engineering.Tokyo:JAEPD,1988:111-116.
[3]GUPTA B,KUNNATH S K.Adaptive Spectra-based Pushover Procedure for Seismic Evaluation of Structures[J].Earthquake Spectra,2000,16(2):367-392.
[4]CHOPRA A K,GOEL R K.A Modal Pushover Analysis Procedure for Estimating Seismic Demands for Buildings[J].Earthquake Engineering and Structural Dynamics,2002,31(3):561-582.
[5]龚思礼.建筑抗震设计手册[M].北京:中国建筑工业出版社,2002. GONG Si-li.Seismic Design Manual[M].Beijing:China Architecture & Building Press,2002.
[6]SHIBATA A,SOZEN M A.Substitute Structure Method for Seismic Design in R/C[J].Journal of the Structure Division,1976,102(1):1-18.
[7]FILIATRAULT A,FOLZ B.Performance-based Seismic Design of Wood Framed Buildings[J].Journal of Structural Engineering,2002,128(1):39-47.
[8]刘 鸣,李世翠,刘伯权.高层建筑抗震设计振型数目选取原则[J].长安大学学报:自然科学版,2009,29(7):73-76. LIU Ming,LI Shi-cui,LIU Bo-quan.Criterion of Mode Number Selection in Seismic Design for High-rise Building Structures[J].Journal of Chang'an University:Natural Science Edition,2009,29(7):73-76.
[9]潘 元,邢国华,吴 涛,等.梁高不等的混凝土中柱节点抗震性能[J].长安大学学报:自然科学版,2010,30(4):60-65. PAN Yuan,XING Guo-hua,WU Tao,et al.Failure Mechanism and Seismic Behavior of Interior Joints with Different Depth Beams[J].Journal of Chang'an University:Natural Science Edition,2010,30(4):60-65.
[10]贡金鑫,李金波,程 玲.锈蚀钢筋混凝土圆柱加固后的抗震性能[J].中国公路学报,2010,23(6):41-48. GONG Jin-xin,LI Jin-bo,CHENG Ling.Seismic Behavior of Strengthened Corrosion-damaged Circular Reinforced Concrete Columns[J].China Journal of Highway and Transport,2010,23(6):41-48.
[11]何世钦,安雪晖,小原孝之,等.配置夹式钢筋的钢筋混凝土柱抗震性能试验[J].中国公路学报,2008,21(4):43-49. HE Shi-qin,AN Xue-hui,OBARA Takayuki,et al.Experiment on Anti-seismic Performance of Reinforced Concrete Columns with Clip Reinforcement[J].China Journal of Highway and Transport,2008,21(4):43-49.
[12]GB 50011—2010,建筑抗震设计规范[S]. GB 50011—2010,Code for Seismic Design of Buildings[S].

Memo

Memo:
-
Last Update: 2012-12-20