|Table of Contents|

Research on Influence of Operation Mode on Geothermal Field Efficiency of Groundwater Heat Pump(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2022年05期
Page:
284-292
Research Field:
基础工程
Publishing date:

Info

Title:
Research on Influence of Operation Mode on Geothermal Field Efficiency of Groundwater Heat Pump
Author(s):
ZHOU Nian-qing1 KONG Ling-xi1 WANG Xiao-qing2 WANG Yang2
(1. Department of Hydraulic Engineering, Tongji University, Shanghai 200092, China; 2. Shanghai Engineering and Technology Research Center of Shallow Geothermal Energy, Shanghai 200072, China)
Keywords:
groundwater heat pump coupled thermal conduction and groundwater seepage geothermal field heat transfixion operation mode
PACS:
TK521
DOI:
10.19815/j.jace.2021.09126
Abstract:
Based on a groundwater heat pump project in Shanghai, a 2D simplified coupled thermal conduction and groundwater seepage numerical model was established to simulate the heat transport process of porous media in the production aquifer by means of finite element analysis tool COMSOL Multiphysics, and the field monitoring data of heat pump operation for 3 years were used to identify and verify the model. The efficiency influenced by cooling/heating load design and pumping/injection mode of heat pump system were discussed on geothermal field under different working conditions in production area, the evolution characteristics of geothermal field during operation of heat pump were predicted and analyzed, and finally the operating effect of the system was evaluated. The results show that when the heat pump system is running according to the original design scheme, the pumping and injection wells have a good short-term operation effect, but the heat transfixion phenomenon will occur at the end of the 7th heating period, which means that long-term operation will not be conducive to the heat production of hot wells. If 20% heating load is reduced and 20% cooling load is increased, the diffusion velocity of cold affected zone is reduced 46.3%, the operation effect of the system is significantly improved, and heat transfixion phenomenon will not occur within nine simulated operating cycles, which indicates that reasonable adjustment of the cooling and heating load is beneficial to long-term stable operation of heat pump system. When the cooling load and heating load is constant, the diffusion velocity of cold affected zone decreases by 9.3% and 15.7% respectively when the circulating water flow decreases by 10% and 20% respectively, the heat transfixion phenomenon is effectively alleviated, and it can still meet the needs of the project for refrigeration and heating. It is further clarified that the pumping and irrigation mode of large temperature difference and small flow should be adopted in the groundwater source heat pump system.

References:

[1] LO RUSSO S,TADDIA G,DABOVE P,et al.Effectiveness of Time-series Analysis for Thermal Plume Propagation Assessment in an Open-loop Groundwater Heat Pump Plant[J].Environmental Earth Sciences,2018,77(18):1-11.
[2]高秀芝,王沣浩,戢坤池,等.热泵供暖技术发展现状及展望[J].制冷与空调,2019,19(5):71-78,83.
GAO Xiu-zhi,WANG Feng-hao,JI Kun-chi,et al.Development Status and Prospects of Heat Pump Heating Technology[J].Refrigeration and Air-conditioning,2019,19(5):71-78,83.
[3]CASASSO A,SETHI R.Modelling Thermal Recycling Occurring in Groundwater Heat Pumps(GWHPs)[J].Renewable Energy,2015,77:86-93.
[4]POPHILLAT W,ATTARD G,BAYER P,et al.Analytical Solutions for Predicting Thermal Plumes of Groundwater Heat Pump Systems[J].Renewable Energy,2020,147:2696-2707.
[5]MILNES E,PERROCHET P.Assessing the Impact of Thermal Feedback and Recycling in Open-loop Groundwater Heat Pump(GWHP)Systems:A Complementary Design Tool[J].Hydrogeology Journal,2013,21(2):505-514.
[6]LO RUSSO S,TADDIA G,GNAVI L,et al.Neural Network Approach to Prediction of Temperatures Around Groundwater Heat Pump Systems[J].Hydrogeology Journal,2014,22(1):205-216.
[7]GANGULY S,MOHAN KUMAR M S,DATE A,et al.Numerical Investigation of Temperature Distribution and Thermal Performance While Charging-discharging Thermal Energy in Aquifer[J].Applied Thermal Engineering,2017,115:756-773.
[8]王鹏杰.多孔介质热渗耦合实验及模拟研究[D].太原:太原理工大学,2015.
WANG Peng-jie.Experiment and Simulation Research on Porous Medium Under Coupled Thermal Conduction and Groundwater Seepage Conditions[D].Taiyuan:Taiyuan University of Technology,2015.
[9]马致远,翟美静,许 勇,等.砂槽模拟浅源热泵的合理井间距及布局优化:以枫林九溪为例[J].水资源与水工程学报,2018,29(4):143-149.
MA Zhi-yuan,ZHAI Mei-jing,XU Yong,et al.Reasonable Well Spacing and Layout Optimization of Shallow Source Heat Pump Using Sand Trough Simulation:A Case Study in Fenglinjiuxi[J].Journal of Water Resources and Water Engineering,2018,29(4):143-149.
[10]LO RUSSO S,GNAVI L,ROCCIA E,et al.Groundwater Heat Pump(GWHP)System Modeling and Thermal Affected Zone(TAZ)Prediction Reliability:Influence of Temporal Variations in Flow Discharge and Injection Temperature[J].Geothermics,2014,51:103-112.
[11]ATTARD G,BAYER P,ROSSIER Y,et al.A Novel Concept for Managing Thermal Interference Between Geothermal Systems in Cities[J].Renewable Energy,2020,145:914-924.
[12]王 洋,王小清,吕 亮.基于监测数据的地下水源热泵系统运行策略优化[J].水利与建筑工程学报,2019,17(5):153-158.
WANG Yang,WANG Xiao-qing,LV Liang.Operation Strategy Optimization of Groundwater Source Heat Pump Based on Monitoring Data[J].Journal of Water Resources and Architectural Engineering,2019,17(5):153-158.
[13]GARCIA-GIL A,MUELA MAYA S,GARRIDO SCHNEIDER E,et al.Sustainability Indicator for the Prevention of Potential Thermal Interferences Between Groundwater Heat Pump Systems in Urban Aquifers[J].Renewable Energy,2019,134:14-24.
[14]郝 豆.地下水源热泵THM耦合模拟及工程应用[D].淮南:安徽理工大学,2019.
HAO Dou.Groundwater Source Heat Pump THM Coupling Simulation and Engineering Application[D].Huainan:Anhui University of Science & Technology,2019.
[15]周彦章,周志芳,傅志敏.地源热泵系统可持续运行地下水热量运移模拟[J].东南大学学报(自然科学版),2009,39(增2):297-303.
ZHOU Yan-zhang,ZHOU Zhi-fang,FU Zhi-min.Simulation of Thermal Transport in Aquifer for the Sustainable Running of GWHP System[J].Journal of Southeast University(Natural Science Edition),2009,39(S2):297-303.
[16]BLAZQUEZ C S,VERDA V,NIETO I M,et al.Analysis and Optimization of the Design Parameters of a District Groundwater Heat Pump System in Turin,Italy[J].Renewable Energy,2020,149:374-383.
[17]FREEDMAN V L,WAICHLER S R,MACKLEY R D,et al.Assessing the Thermal Environmental Impacts of an Groundwater Heat Pump in Southeastern Washington State[J].Geothermics,2012,42:65-77.
[18]李海岭,周雨泽,曹亚新,等.基于地下水压采目标的地下水源热泵系统井群调控方案[J].南水北调与水利科技(中英文),2020,18(5):165-173.
LI Hai-ling,ZHOU Yu-ze,CAO Ya-xin,et al.Controlling Plan of Well Group Operation of Groundwater Source Heat Pump System with the Target of Groundwater Pressure Recovery[J].South-to-north Water Transfers and Water Science & Technology,2020,18(5):165-173.
[19]GAO Q,ZHOU X Z,JIANG Y,et al.Numerical Simulation of the Thermal Interaction Between Pumping and Injecting Well Groups[J].Applied Thermal Engineering,2013,51(1/2):10-19.
[20]骆祖江,李 伟,王 琰,等.地下水源热泵系统热平衡模拟三维数值模型[J].农业工程学报,2014,30(2):198-204.
LUO Zu-jiang,LI Wei,WANG Yan,et al.Three-dimensional Numerical Model for Heat Balance Simulation of Ground-water Heat Pump[J].Transactions of the Chinese Society of Agricultural Engineering,2014,30(2):198-204.
[21]周丹坤,李晓昭,常晓军.COMSOL平台在城市地下多种资源相互影响分析中的应用[J].吉林大学学报(地球科学版),2021,51(2):526-532.
ZHOU Dan-kun,LI Xiao-zhao,CHANG Xiao-jun.Application of COMSOL Platform in Analysis of Interaction of Urban Underground Multiple Resources[J].Journal of Jilin University(Earth Science Edition),2021,51(2):526-532.
[22]PARK D K,KAOWN D,LEE K K.Development of a Simulation-optimization Model for Sustainable Operation of Groundwater Heat Pump System[J].Renewable Energy,2020,145:585-595.
[23]曾锦雯.地下水源热泵系统土壤换热特性研究及运行优化[D].北京:北京建筑大学,2020.
ZENG Jin-wen.Investigation of Heat Seepage Transfer of Aquifer with Pumping and Recharge in Ground Water Heat Pump System[D].Beijing:Beijing University of Civil Engineering and Architecture,2020.
[24]陈必光.地热对井裂隙岩体中渗流传热过程数值模拟方法研究[D].北京:清华大学,2014.
CHEN Bi-guang.Study on Numerical Methods for Coupled Fluid Flow and Heat Transfer in Fractured Rocks of Doublet System[D].Beijing:Tsinghua University,2014.

Memo

Memo:
-
Last Update: 2022-09-30