|Table of Contents|

Fire Resistance of Square Steel Reinforced Concrete-filled Stainless Steel Tube Columns Embedded with Cross-section Steel(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2019年03期
Page:
66-73
Research Field:
Publishing date:

Info

Title:
Fire Resistance of Square Steel Reinforced Concrete-filled Stainless Steel Tube Columns Embedded with Cross-section Steel
Author(s):
LIU Yan-zhi1 DENG Ji-qian1 TAN Qing-hua2
(1. College of Civil Engineering, Hunan University, Changsha 410082, Hunan, China; 2. College of Aerospace Science, National University of Defense Technology, Changsha 410073, Hunan, China)
Keywords:
steel reinforced concrete-filled stainless steel tube column fire resistance temperature field numerical analysis
PACS:
TU398.9
DOI:
-
Abstract:
The steel reinforced concrete-filled stainless steel tube column was composed by embedding profile steel in the concrete-filled stainless steel tube column, which reduced the amount of stainless steel and made the column have better ductility and fire resistance. The fire resistance of square steel reinforced concrete-filled stainless steel tube column embedded with profile steel was studied by finite element simulation. Firstly, the finite element model of fire resistance performance of square steel reinforced concrete-filled stainless steel tube column under fire was established, and the temperature field and fire resistance data of relevant tests were used to fully verify the model. Based on the validated finite element model, the temperature history, axial deformation-time relationship, typical failure modes and section internal force redistribution of a typical steel reinforced concrete-filled stainless steel tube column under different load ratios were analyzed, and the working mechanism under fire was defined. At the same time, the comparative analysis with concrete-filled stainless steel tube columns with equal steel content was carried out. The results show that the embedded profile steel is helpful to improve the axial stiffness and lateral stiffness of columns at high temperature. The failure modes of steel reinforced concrete-filled stainless steel tubular columns are manifested as axial compression failure. Under low fire load ratio, because partial profile steel shares the load transferred from stainless steel, it allows stainless steel to deteriorate at higher temperatures, thereby improving its fire resistance. The lower the fire load ratio, the more remarkable the improvement effect is.

References:


[1] 韩林海,陶 忠,王文达.现代组合结构和混合结构:试验、理论和方法[M].北京:科学出版社,2009.
HAN Lin-hai,TAO Zhong,WANG Wen-da.Advanced Composite and Mixed Structures:Testing,Theory and Design Approach[M].Beijing:Science Press,2009.
[2]GARDNER L.The Use of Stainless Steel in Structures[J].Progress in Structural Engineering and Materials,2005,7(2):45-55.
[3]BADDOO N R.Stainless Steel in Construction:A Review of Research,Applications,Challenges and Opportunities[J].Journal of Constructional Steel Research,2008,64(11):1199-1206.
[4]韩林海,宋天诣.钢-混凝土组合结构抗火设计原理[M].北京:科学出版社,2012.
HAN Lin-hai,SONG Tian-yi.Fire Safety Design Theory of Steel-concrete Composite Structures[M].Beijing:Science Press,2012.
[5]GB/T 9978—1999,建筑构件耐火试验方法[S].
GB/T 9978—1999,Fire-resistance Tests — Elements of Building Construction[S].
[6]PATEL V I,LIANG Q Q,HADI M N S.Nonlinear Analysis of Axially Loaded Circular Concrete-filled Stainless Steel Tubular Short Columns[J].Journal of Constructional Steel Research,2014,101:9-18.
[7]DABAON M A,EL-BOGHDADI M H,HASSANEIN M F.Experimental Investigation on Concrete-filled Stainless Steel Stiffened Tubular Stub Columns[J].Engineering Structures,2009,31(2):300-307.
[8]UY B,TAO Z,HAN L H.Behaviour of Short and Slender Concrete-filled Stainless Steel Tubular Columns[J].Journal of Constructional Steel Research,2011,67(3):360-378.
[9]HAN L H,CHEN F,LIAO F Y,et al.Fire Performance of Concrete Filled Stainless Steel Tubular Columns[J].Engineering Structures,2013,56:165-181.
[10]ISO 834-1:1991,Fire-resistance Tests — Elements of Building Construction — Part 1:General Requirements[S].
[11]TAO Z,GHANNAM M.Heat Transfer in Concrete-filled Carbon and Stainless Steel Tubes Exposed to Fire[J].Fire Safety Journal,2013,61:1-11.
[12]TAO Z,GHANNAM M,SONG T Y,et al.Experimental and Numerical Investigation of Concrete-filled Stainless Steel Columns Exposed to Fire[J].Journal of Constructional Steel Research,2016,118:120-134.
[13]HAN L H,TAN Q H,SONG T Y.Fire Performance of Steel Reinforced Concrete Columns[J].Journal of Structural Engineering,2015,141(4):04014128.
[14]EN 1992-1-2:2004,Eurocode 2:Design of Concrete Structures — Part 1-2:General Rules — Structural Fire Design[S].
[15]EN 1993-1-2:2005,Eurocode 3:Design of Steel Structures — Part 1-2:General Rules — Structural Fire Design[S].
[16]GARDNER L,NG K T.Temperature Development in Structural Stainless Steel Sections Exposed to Fire[J].Fire Safety Journal,2006,41(3):185-203.
[17]SONG T Y,HAN L H,YU H X.Concrete Filled Steel Tube Stub Columns Under Combined Temperature and Loading[J].Journal of Constructional Steel Research,2010,66(3):369-384.
[18]韩林海.钢管混凝土结构——理论与实践[M].3版.北京:科学出版社,2016.
HAN Lin-hai.Concrete Filled Steel Tubular Structures — Theory and Practice[M].3rd ed.Beijing:Science Press,2016.
[19]CECS 410:2015,不锈钢结构技术规程[S].
CECS 410:2015,Technical Specification for Stainless Steel Structures[S].
[20]ROE W.Behavior and Design of Concrete Filled Stainless Steel Columns[D].Wollongong:University of Wollongong,2006.