|Table of Contents|

Experiment on Flexural Behavior and Strengthening of Glued Timber Beams with Small Span to Height Ratio(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2019年06期
Page:
26-34
Research Field:
Publishing date:

Info

Title:
Experiment on Flexural Behavior and Strengthening of Glued Timber Beams with Small Span to Height Ratio
Author(s):
CHEN Bo-wang1 LIU Chen-cheng1 LIU Jian-wen2 WAN Ya-ni2 LYU Wei-lei1 LIU Yu-qi1
(1. School of Civil Engineering, Central South University of Forestry and Technology, Changsha 410004, Hunan, China; 2. Hunan Architectural Design Institute Limited Company, Changsha 410012, Hunan, China)
Keywords:
glued timber beam with small span to high ratio shear failure along grain screw steel plate ultimate bearing capacity
PACS:
TU366.3
DOI:
-
Abstract:
In order to study the mechanical performance of the glued wood beam used in engineering, the flexural bearing capacity tests on 9 wood beams with the span to height ratio of 12 in 4 groups were carried by means of unreinforced, pasting steel at the bottom, screwing screws in the bottom bending shear area and pasting steel plates in the middle of both sides. The failure forms, load-displacement curves and other properties of the specimens were obtained through tests, and the mechanical properties and the distribution law of mid-span strain of the strengthened wood beam were analyzed. The limit span to height ratio of wood beam subjected to tensile and shear failure in three-point bending test was proposed. In the validation of cross section of bending beam strain distribution basic according with plane section assumption, the formula for calculating ultimate bearing capacity of glued timber beams with small span to height ratio and enhance member when shear failure along grain in the three-point bending test was proposed. The results show that the failure mode of the small span to height ratio glued wood beam is shear failure along the grain, and there is no sign of failure, and the failure surface basically occurs in the netural axis and the lower location of the wooden beam. The area of compression zone of bottom bonded steel beam increases, the neutral axis moves down, and the ultimate bearing capacity and stiffness both increase. The shear resistance and ultimate bearing capacity of the beam can be improved by screwing screws into the bottom of the beam and attaching steel plates to the side. The results show that the errors between the theoretical values and the measured values are mostly below 20%, and the theoretical values are safer than the measured values, which can provide reference for the design and engineering application of such components.

References:

[1] 刘伟庆,杨会峰.工程木梁的受弯性能试验研究[J].建筑结构学报,2008,29(1):90-95.
LIU Wei-qing,YANG Hui-feng.Experimental Study on Flexural Behavior of Engineering Timber Beams[J].Journal of Building Structures,2008,29(1):90-95.
[2]周先雁,曹 磊,曾 丹,等.胶合木梁抗弯承载力分析[J].建筑结构,2015,45(22):91-96.
ZHOU Xian-yan,CAO Lei,ZENG Dan,et al.Flexural Capacity Analysis of Glulam Beams[J].Building Structure,2015,45(22):91-96.
[3]张 庆.层板胶合木梁受力性能的试验探究[J].四川建材,2018,44(9):76-77.
ZHANG Qing.Experimental Study on Mechanical Properties of Laminated Plywood Beams[J].Sichuan Building Materials,2018,44(9):76-77.
[4]FERRIER E,LABOSSIERE P,NEALE K.Mechanical Behavior of an Innovative Hybrid Beam Made of Glulam and Ultrahigh-performance Concrete Reinforced with FRP or Steel[J].Journal of Composites for Construction,2010,14(2):217-228.
[5]MANALO A C,ARAVINTHAN T,KARUNASENA W.Flexural Behaviour of Glue-laminated Fibre Composite Sandwich Beams[J].Composite Structures,2010,92(11):2703-2711.
[6]KHORSANDNIA N,VALIPOUR H R,FOSTER S,et al.A Force-based Frame Finite Element Formulation for Analysis of Two-and Three-layered Composite Beams with Material Non-linearity[J].International Journal of Non-linear Mechanics,2014,62:12-22.
[7]GB/T 50329—2012,木结构试验方法标准[S].
GB/T 50329—2012,Standard for Test Methods of Timber Structures[S].
[8]杨会峰,刘伟庆.FRP增强胶合木梁的受弯性能研究[J].建筑结构学报,2007,28(1):64-71.
YANG Hui-feng,LIU Wei-qing.Study on Flexural Behavior of FRP Reinforced Glulam Beams[J].Journal of Building Structures,2007,28(1):64-71.
[9]杨昕卉,薛 伟,郭 楠.钢板增强胶合木梁的抗弯性能[J].吉林大学学报:工学版,2017,47(2):468-477.
YANG Xin-hui,XUE Wei,GUO Nan.Bending Performance of Glued-lumber Beam Reinforced with Steel Plate[J].Journal of Jilin University:Engineering Edition,2017,47(2):468-477.
[10]曹 磊,陈伯望.胶合木梁抗剪性能研究综述[J].工程力学,2018,35(6):1-5,14.
CAO Lei,CHEN Bo-wang.Research Review of Shear Behavior of Glulam[J].Engineering Mechanics,2018,35(6):1-5,14.
[11]谢启芳,薛建阳,赵鸿铁,等.碳纤维布加固木梁抗剪性能的试验研究[J].工业建筑,2012,42(6):88-91.
XIE Qi-fang,XUE Jian-yang,ZHAO Hong-tie,et al.Experimental Study on Shear Behavior of Timber Beam Strengthened with CFRP Sheet[J].Industrial Construction,2012,42(6):88-91.
[12]淳 庆,潘建伍.碳-芳混杂纤维布加固木梁抗剪性能分析[J].解放军理工大学学报:自然科学版,2011,12(6):654-658.
CHUN Qing,PAN Jian-wu.Shear Behavior of Timber Strengthened with CFRP/AFRP Hybrid FRP Sheet[J].Journal of PLA University of Science and Technology:Natural Science Edition,2011,12(6):654-658.
[13]SVECOVA D,EDEN R J.Flexural and Shear Strengthening of Timber Beams Using Glass Fiber Reinforced Polymer Bars — An Experimental Investigation[J].Canadian Journal of Civil Engineering,2004,31(1):45-55.
[14]许清风.粘贴CFRP布加固木梁受剪性能的试验研究[J].工业建筑,2011,41(增):239-243.
XU Qing-feng.Experimental Study on Shear Behavior of Wood Beams Strengthened with CFRP Sheets[J].Industrial Construction,2011,41(S):239-243.
[15]ASTM D 198-09,Standard Test Methods of Static Tests of Lumber in Structural Sizes[S].
[16]谢启芳.中国木结构古建筑加固的试验研究及理论分析[D].西安:西安建筑科技大学,2007.
XIE Qi-fang.Experimental Study and Theoretical Analysis of Strengthening for Chinese Ancient Timber Buildings[D].Xi'an:Xi'an University of Architecture and Technology,2007.
[17]木结构设计手册编辑委员会.木结构设计手册[M].3版.北京:中国建筑工业出版社,2005.
Editorial Committee of Timber Engineering Manual.Timber Engineering Manual[M].3rd ed.Beijing:China Architecture & Building Press,2005.
[18]GB 50005—2003,木结构设计规范[S].
GB 50005—2003,Code for Design of Timber Structures[S].
[19]GB 50005—2017,木结构设计标准[S].
GB 50005—2017,Standard for Design of Timber Structures[S].
[20]TRIANTAFILLOU T C.Composites:A New Possibility for the Shear Strengthening of Concrete,Masonry and Wood[J].Composites Science and Technology,1998,58(8):1285-1295.

Memo

Memo:
-
Last Update: 2019-11-26