|Table of Contents|

Study on Fire Resistance of Axially Compressed Partially-encased Composite Steel and Concrete Columns with Different Strengthening Measures(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2022年02期
Page:
19-29
Research Field:
防灾减灾工程
Publishing date:

Info

Title:
Study on Fire Resistance of Axially Compressed Partially-encased Composite Steel and Concrete Columns with Different Strengthening Measures
Author(s):
HU Chen1 ZHANG Hui-jie1 WANG Jing-feng23 SUN Tong2 LIU Yong23
(1. Research Institute of Economics and Technology of State Grid Anhui Electric Power Co., Ltd., Hefei 230009, Anhui, China; 2. School of Civil and Engineering, Hefei University of Technology, Hefei 230009, Anhui, China; 3. Advanced Steel Structure Technology and Industrialization Collaborative Innovation Center of Anhui, Hefei University of Technology, Hefei 230009, Anhui, China)
Keywords:
PEC column fire resistance performance axial compression strengthening measure fire resistance limit
PACS:
TU398
DOI:
10.19815/j.jace.2021.08082
Abstract:
Due to the exposed steel flanges, the fire resistance limit of partially-encased composite steel and concrete(PEC)columns is difficult to meet the design requirements. In order to explore the strengthening method of the fire resistance performance of PEC columns and obtain the economic and reasonable strengthening measures, the ABAQUS was used to establish the temperature field and the thermodynamic finite element models of PEC columns under axial compression. The reliability of the model was verified using the existing test data, and the temperature field, stress mechanism and failure mode of PEC column in fire were investigated. The parameter analysis was carried out to study the influence of parameters such as load ratio, longitudinal reinforcement ratio, flange area ratio, section size, slenderness ratio and fireproof coating thickness on the fire resistance limit of PEC columns. The results show that the fire resistance limit of PEC columns will improve with the decrease of the load ratio, slenderness ratio and flange area ratio and the increase of the fireproof coating thickness and section size. A simplified equation is regressed based on the parametric analyses to predict the fire resistance limit of PEC column considering the influence of fire proof coating thickness. The research results will provide a scientific basis for the fire resistance design of the PEC components.

References:

[1] 李鹏宇.H型钢部分外包混凝土组合短柱抗震性能的试验研究[D].包头:内蒙古科技大学,2009.
LI Peng-yu.Experimental Study on Seismic Behavior of H-beam Partially Clad Concrete Composite Short Columns[D].Baotou:Inner Mongolia University of Science and Technology,2009.
[2]赵根田,周易晖.部分包裹混凝土柱抗震性能分析[J].山西农经,2017(4):127-128.
ZHAO Gen-tian,ZHOU Yi-hui.Analysis of Seismic Performance of Partially Wrapped Concrete Columns[J].Shanxi Agricultural Economy,2017(4):127-128.
[3]林德慧,陈以一.部分填充钢-混凝土组合柱整体稳定分析[J].工程力学,2019,36(增1):71-77,85.
LIN De-hui,CHEN Yi-yi.Overall Stability Analysis of Partially Encased Composite Columns[J].Engineering Mechanics,2019,36(S1):71-77,85.
[4]WAINMAN D E,TOMLINSON L N.BS476:Part 21 Fire Resistance Tests Summary of Data Obtained During Tests on Web Encased Columns[R].Rotherham:Swinden Laboratories,1994.
[5]MOURA CORREIA A J P,RODRIGUES J P C.Fire Resistance of Partially Encased Steel Columns with Restrained Thermal Elongation[J].Journal of Constructional Steel Research,2011,67(4):593-601.
[6]毛小勇,徐悦军,行盼娟.标准升温条件下PEC柱耐火极限理论分析及简化计算[J].防灾减灾工程学报,2012,32(1):45-49.
MAO Xiao-yong,XU Yue-jun,XING Pan-juan.Theoretic Model and Simplified Calculation Method of Fire Resistance of Partially Encaed Concrete(PEC)Columns[J].Journal of Disaster Prevention and Mitigation Engineering,2012,32(1):45-49.
[7]徐悦军,毛小勇.标准升温下PEC柱的耐火极限分析[J].苏州科技学院学报(工程技术版),2011,24(2):24-27.
XU Yue-jun,MAO Xiao-yong.An Analysis on Fire Resistance Limit of PEC Columns Under Standard Warming Conditions[J].Journal of Suzhou University of Science and Technology(Engineering and Technology),2011,24(2):24-27.
[8]毛小勇,满建政,金晓飞.约束PEC柱轴力变化规律及影响因素[J].消防科学与技术,2012,31(5):443-446.
MAO Xiao-yong,MAN Jian-zheng,JIN Xiao-fei.Variation of Axial Force and Analysis of Related Factors in Restrained PEC Columns Subjected to Standard Fire[J].Fire Science and Technology,2012,31(5):443-446.
[9]满建政,毛小勇.标准升温下轴向约束PEC柱耐火极限及影响因素分析[J].苏州科技学院学报(工程技术版),2012,25(2):42-45.
MAN Jian-zheng,MAO Xiao-yong.Fire Resistance Limit and Its Influence Factors of Axial Restrained PEC Columns Subjected to Standard Fire[J].Journal of Suzhou University of Science and Technology(Engineering and Technology),2012,25(2):42-45.
[10]金晓飞,毛小勇.弯矩分布模式对约束PEC柱抗火性能的影响[J].苏州科技学院学报(工程技术版),2012,25(3):23-27.
JIN Xiao-fei,MAO Xiao-yong.Influence of Bending Moment Distribution Mode on Fire Behavior of Restrained PEC Columns[J].Journal of Suzhou University of Science and Technology(Engineering and Technology),2012,25(3):23-27.
[11]LIE T T.Fire Resistance of Circular Steel Columns Filled with Bar-reinforced Concrete[J].Journal of Structural Engineering,1994,120(5):1489-1509.
[12]刘 用.采用角钢连接件的U形钢-混凝土组合梁抗弯与抗火性能[D].哈尔滨:哈尔滨工业大学,2020.
LIU Yong.Flexural Behaviour and Fire Resistance of Composite Beams with Ushaped Steel Girder and Angle Connectors[D].Harbin:Harbin Institute of Technology,2020.
[13]李国强,韩林海,楼国彪.钢结构及钢-混凝土组合结构抗火设计[M].北京:中国建筑工业出版社,2006.
LI Guo-qiang,HAN Lin-hai,LOU Guo-biao.Fire Resistance Design of Steel Structure and Steel-concrete Composite Structure[M].Beijing:China Architecture & Building Press,2006.
[14]LIE T T,LRWIN R J.Fire Resistance of Rectangular Steel Columns Filled with Bar-reinforced Concrete[J].Journal of Structural Engineering,1995,121(5):797-805.
[15]Eurocode 3:Design of Steel Structures-Part 1-2:General Rules Structures Fire Design:EN 1993-1-2:2005[S].London:British Standards Institution,2005.
[16]金晓飞.约束PEC柱绕强轴的抗火性能研究[D].苏州:苏州科技学院,2012.
JIN Xiao-fei.Analysis of Restrained PEC Columns Around Strong Axis on Fire-resistant Performance[D].Suzhou:Suzhou University of Science and Technology,2012.
[17]徐腾飞,戈孝聪.高温下PEC柱与普通H型钢柱翼缘屈曲性能比较[J].江苏建筑,2017(3):32-35.
XU Teng-fei,GE Xiao-cong.Comparison of Flange Buckling Behavior Between PEC Column and Normal H-shape Steel Column Under High Temperature[J].Jiangsu Construction,2017(3):32-35.
[18]吴耀鹏,张 旭,李晓蕾.典型受火方式下型钢混凝土异形柱耐火极限研究[J].钢结构,2017,32(11):117-122.
WU Yao-peng,ZHANG Xu,LI Xiao-lei.Research on the Fire Endurance of SRC Special-shaped Column in Typical Fire Exposure Cases[J].Steel Construction,2017,32(11):117-122.
[19]郑蝉蝉,李引擎,王广勇.型钢混凝土约束柱耐火性能研究[J].建筑科学,2016,32(3):81-88.
ZHENG Chan-chan,LI Yin-qing,WANG Guang-yong.Fire Performance Study of Steel Reinforced Concrete Restrained Columns[J].Building Science,2016,32(3):81-88.
[20]刘 猛,张 斌,李蒙杰.H型钢混凝土柱的抗火性能数值模拟分析[J].建筑科学,2018,34(5):113-117,130.
LIU Meng,ZHANG Bin,LI Meng-jie.Numerical Simulation Analysis of Fire Resistance of H-shaped Steel Reinforced Concrete Columns[J].Building Science,2018,34(5):113-117,130.
[21]杜明淮.不同涂层厚度对火灾下简支钢梁耐火性能的影响分析[D].合肥:合肥工业大学,2013.
DU Ming-huai.The Analysis of Impact on Simply Supported Steel Beam's Fire Resistance Performance Under Fire in Different Coating Thickness[D].Hefei:Hefei University of Technology,2013.
[22]高 宇,毛小勇.火灾荷载比对约束PEC柱(绕弱轴)抗火性能影响研究[J].苏州科技学院学报(工程技术版),2016,29(3):23-27.
GAO Yu,MAO Xiao-yong.Influence of Load Ratio on the Fire Performance of Restrained PEC Columns(Around the Weak Axis)[J].Journal of Suzhou University of Science and Technology(Engineering and Technology),2016,29(3):23-27.
[23]赵根田,郝志强,朱晓娟,等.部分包裹混凝土偏心受压短柱受力性能试验研究[J].内蒙古科技大学学报,2008,27(2):178-182.
ZHAO Gen-tian,HAO Zhi-qiang,ZHU Xiao-juan,et al.Experiment Study on the Behavior of Partially Encased Concrete Short Columns Subjected to Eccentric Compression[J].Journal of Inner Mongolia University of Science and Technology,2008,27(2):178-182.
[24]李补拴,张宇鸣,赵根田,等.不同加载方式下的PEC柱(强轴)抗震性能试验研究[J].建筑钢结构进展,2021,23(8):43-52.
LI Bu-shuan,ZHANG Yu-ming,ZHAO Gen-tian,et al.An Experimental Study on the Seismic Performance of PEC Columns(Strong Axis)Under Different Loading Patterns[J].Progress in Steel Building Structures,2021,23(8):43-52.
[25]朱晋德.基于升降温全过程的PEC柱耐火性能指标研究[D].苏州:苏州科技大学,2017.
ZHU Jin-de.Research on Fire Resistance Indicators of PEC Column Based on the Whole Process of Heating and Cooling Phases[D].Suzhou:Suzhou University of Science and Technology,2017.
[26]张萌萌.型钢混凝土柱的耐火极限研究[D].哈尔滨:哈尔滨工程大学,2017.
ZHANG Meng-meng.Research on Fire Endurance of Steel Reinforced Concrete Columns[D].Harbin:Harbin Engineering University,2017.
[27]徐悦军.PEC柱抗火性能及设计方法研究[D].苏州:苏州科技学院,2011.
XU Yue-jun.Fire Performance and Design Method of Partial Encaed Concrete(PEC)Columns[D].Suzhou:Suzhou University of Science and Technology,2011.
[28]王忠铖.型钢混凝土柱耐火性能研究与优化方法[D].邯郸:河北工程大学,2015.
WANG Zhong-cheng.Fire Resistance Research of Steel Reinforced Concrete Columns and Optimization Method[D].Handan:Hebei University of Engineering,2015.

Memo

Memo:
-
Last Update: 2022-03-20