|Table of Contents|

Analysis of high frequency and amplitude variation law of axial compression ratio of central column in subway station and hysteretic performance degradation(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2025年05期
Page:
74-84
Research Field:
建筑结构
Publishing date:

Info

Title:
Analysis of high frequency and amplitude variation law of axial compression ratio of central column in subway station and hysteretic performance degradation
Author(s):
LIU Zhichen1 DENG Peng12 CHEN Renpeng12 KE Wenhai3
(1. College of Civil Engineering, Hunan University, Changsha 410082, Hunan, China; 2. Hunan Engineering Research Central for Advanced Technology and Intelligent Equipment for Underground Space Development, Hunan University, Changsha 410082, Hunan, China; 3. School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang 330013, Jiangxi, China)
Keywords:
central column finite element model variable axial compression ratio amplitude frequency hysteretic performance
PACS:
TU924
DOI:
10.19815/j.jace.2024.02019
Abstract:
Based on the finite element model of subway station, the evolution law of axial compression ratio of central column top under different seismic design schemes was obtained through nonlinear time history analysis, and the numerical quantification was carried out. Based on the quantified evolution mode of variable axial compression ratio, the influence of variable frequency, amplitude, and phase of variable axial compression ratio on hysteretic properties of central column was explored through the experimental verified central column model, and the concrete damage of central column was discussed. The results show that the horizontal displacement of the central column top and the vertical axial compression ratio change asynchronously, the latter change frequency is faster, the latter change frequency is about 1.4-3.8 times of the former, and the vertical axial compression ratio change amplitude is 0.08-0.68. Compared with the vertical constant axial compression ratio, the high variable axial compression ratio applied on the central column top has a significant adverse effect on the bearing capacity, energy dissipation, and stiffness degradation of column, and aggravates the concrete compression damage of column. When the frequency of vertical axial compression ratio is 3 and the amplitude is large, the damage is particularly obvious, and the bearing capacity and energy dissipation are reduced by about 50% and 74% respectively.

References:

[1] 曾佳明,朱忠义,吕 辉,等.考虑土-结构相互作用的大跨度空间结构抗震研究进展[J].建筑科学与工程学报, 2024, 41(1): 69-82.
ZENG Jiaming, ZHU Zhongyi, LYU Hui, et al. Research progress on seismic resistance of large-span spatial structures considering soil-structure interaction[J]. Journal of Architecture and Civil Engineering, 2024, 41(1): 69-82.
[2]陈湘生,付艳斌,陈 曦,等.地下空间施工技术进展及数智化技术现状[J].中国公路学报,2022,35(1):1-12.
CHEN Xiangsheng, FU Yanbin, CHEN Xi, et al. Progress in underground space construction technology and technical challenges of digital intelligence[J]. China Journal of Highway and Transport, 2022, 35(1): 1-12.
[3]YAMATO T, UMEHARA T, AOKI H, et al. Damage to Daikai subway station of Kobe rapid transit system and estimation of its reason during the 1995 Hyogoken-Nanbu earthquake[J]. Doboku Gakkai Ronbunshu, 1996, 1996(537): 303-320.
[4]ZHUANG H Y, ZHAO C, CHEN S, et al. Seismic performance of underground subway station with sliding between column and longitudinal beam[J]. Tunnelling and Underground Space Technology, 2020, 102: 103439.
[5]AN X H, SHAWKY A A, MAEKAWA K. The collapse mechanism of a subway station during the Great Hanshin earthquake[J]. Cement and Concrete Composites, 1997, 19(3): 241-257.
[6]刘如山,邬玉斌,杜修力.用纤维模型对地下结构地震破坏的数值模拟分析[J].北京工业大学学报,2010,36(11):1488-1495.
LIU Rushan, WU Yubin, DU Xiuli. Numerical simulation analysis on earthquake damage of underground structure with fiber model[J]. Journal of Beijing University of Technology, 2010, 36(11): 1488-1495.
[7]FERDOUS W, MANALO A, PEAURIL J, et al. Testing and modelling the fatigue behaviour of GFRP composites — effect of stress level,stress concentration and frequency[J]. Engineering Science and Technology, an International Journal, 2020, 23(5): 1223-1232.
[8]ZHAO W C, YE J H, QIAN J. Dynamic behavior and damage mechanisms of reinforced concrete piers subjected to truck impact[J]. Engineering Failure Analysis, 2021, 121: 105158.
[9]XU G S, WU B, JIA D D, et al. Quasi-static tests of RC columns under variable axial forces and rotations[J]. Engineering Structures, 2018, 162: 60-71.
[10]RODRIGUES H, FURTADO A, ARÊDE A. Behavior of rectangular reinforced-concrete columns under biaxial cyclic loading and variable axial loads[J]. Journal of Structural Engineering, 2016, 142(1): 04015085.
[11]WU B Y, SUN G J, LI H J, et al. Effect of variable axial load on seismic behaviour of reinforced concrete columns[J]. Engineering Structures, 2022, 250: 113388.
[12]郭玉荣,梁康殷,吕 聪.双轴加载下变轴力大尺寸钢筋混凝土柱抗震性能试验研究[J].建筑结构学报,2024,45(5):155-163.
GUO Yurong, LIANG Kangyin, LU Cong. Experimental study on seismic behavior of large size reinforced concrete columns under biaxial loading and variable axial loads[J]. Journal of Building Structures, 2024, 45(5): 155-163.
[13]ZHUANG H Y, HU Z H, WANG X J, et al. Seismic responses of a large underground structure in liquefied soils by FEM numerical modelling[J]. Bulletin of Earthquake Engineering, 2015, 13(12): 3645-3668.
[14]地下结构抗震设计标准:GB/T 51336—2018[S].北京:中国建筑工业出版社,2018.
Seismic design standards for underground structures: GB/T 51336—2018[S]. Beijing: China Architecture & Building Press, 2018.
[15]王海东,常广乐,盛旺成.近场水平、竖向地震共同作用下地基-基础-RC框架结构抗震性能研究[J].地震工程与工程振动,2017,37(1):192-198.
WANG Haidong, CHANG Guangle, SHENG Wangcheng. Seismic performance of soil-foundation-RC frame under near-fault horizontal and vertical earthquake[J]. Earthquake Engineering and Engineering Dynamics, 2017, 37(1): 192-198.
[16]YIN Y P. Vertical acceleration effect on landsides triggered by the Wenchuan earthquake, China[J]. Environmental Earth Sciences, 2014, 71(11): 4703-4714.
[17]混凝土结构设计规范:GB 50010—2010[S].北京:中国建筑工业出版社,2004.
Code for design of concrete structures: GB 50010—2010[S]. Beijing: China Architecture & Building Press, 2004.
[18]MANDER J B, PRIESTLEY M J N, PARK R. Theoretical stress-strain model for confined concrete[J].Journal of Structural Engineering, 1988, 114(8): 1804-1826.
[19]LIU Z C, DENG P, LI Y L, et al. Analysis of axial force variations and seismic performance of subway station columns under earthquake loading[J]. Soil Dynamics and Earthquake Engineering, 2024, 186: 108878.
[20]DI J, FAN J H, ZHOU X H, et al. Hysteretic behavior of composite bridge columns with plastic hinge enhanced by engineered cementitious composite jacket for seismic resistance[J]. Engineering Structures, 2022, 251: 113532.
[21]HASSAN W M, ELMORSY M. Database trends and critical review of seismic performance tests on high strength steel reinforced concrete components[J]. Engineering Structures, 2021, 239: 112092.

Memo

Memo:
-
Last Update: 2025-09-25