|Table of Contents|

Tensile test study of high-strength steel plate single-sided bolted steel connections considering construction deviation(PDF)

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

Issue:
2024年05期
Page:
82-92
Research Field:
建筑结构
Publishing date:

Info

Title:
Tensile test study of high-strength steel plate single-sided bolted steel connections considering construction deviation
Author(s):
DUAN Liusheng1 ZHOU Youli1 DING Taotao1 WU Nan1 ZHOU Tianhua1 PAN Hong2 ZHANG Huabing3
(1. School of Civil Engineering, Chang'an University, Xi'an 710061, Shaanxi, China; 2. Western Architectural Seismic Survey, Design and Research Institute Co., Ltd, Xi'an 710054, Shaanxi, China; 3. Southwest Municipal Engineering Design & Research Institute of China, Chengdu 610036, Sichuan, China)
Keywords:
steel connection axis deviation relative angle anchorage length
PACS:
TU398
DOI:
10.19815/j.jace.2022.10004
Abstract:
In order to study the tensile performance of high-strength steel plate single-sided bolted steel connections considering construction deviation,the monotonic tensile tests were conducted for 26 specimens. The study variables included bolt strength grades, steel bar diameters, preloads, anchorage lengths, steel bar axis deviation, and relative turning angle of steel bar. The failure mode, load-displacement curves, ultimate bearing capacity and deformation capacity of connection were analyzed. The results show that three types of steel bars with different diameters all exhibit two types of failure phenomena: steel bar breakage and plow trench pull-out. When four 12.9 grade bolts are used for the connection, the critical anchorage length of 12 mm diameter steel bars is between 4d and 5d(d is the diameter of steel bar). For the 14 mm diameter bars, the 12.9 grade bolts are difficult to work well, and the damage is all in the form of pullout damage. It is recommended to use 6 bolts to achieve equal strength connection when connecting steel bars with diameter of 12 mm and 14 mm. When the anchorage length is same, increasing the preload or increasing the strength of the bolts can effectively improve the tensile strength of the joint. When using bolts of grade 14.9, the anchorage length of the steel bar with diameter of 14 mm is between 3d and 4d. Under the same anchorage length and preload conditions, when the relative angle is 45°, the connector exhibits pull-out failure, while 0°and 90°both exhibit tensile failure. Under the same conditions, the anchorage length increases and the ultimate load capacity decreases for wide slotted connectors compared with narrow slotted connectors, so it is recommended to increase the thickness of cover to give full play to the performance of connectors.

References:

[1] 石 棚,王 浩,柳家为,等.钢筋插入式波纹管浆锚连接受力性能数值分析[J].哈尔滨工程大学学报,2021,42(6):810-817.
SHI Peng,WANG Hao,LIU Jiawei,et al.Numerical analysis of anchorage properties of grouting connection of preburied bellows with steel bars inserted[J].Journal of Harbin Engineering University,2021,42(6):810-817.
[2]王 浩,柳家为,石 棚,等.钢筋-金属波纹管灌浆连接的锚固性能试验研究[J].东南大学学报(自然科学版),2020,50(2):215-221.
WANG Hao,LIU Jiawei,SHI Peng,et al.Experimental study on anchorage performance of rebar-corrugated metal duct for grout splicing[J].Journal of Southeast University(Natural Science Edition),2020,50(2):215-221.
[3]孙 建,邱洪兴,蒋洪波.螺栓连接装配式一字形钢筋混凝土剪力墙承载力分析[J].建筑结构学报,2019,40(8):23-30.
SUN Jian,QIU Hongxing,JIANG Hongbo.Analysis on load bearing capacities of rectangular precast reinforced concrete shear wall assembled by high strength bolts[J].Journal of Building Structures,2019,40(8):23-30.
[4]庞 瑞,梁书亭,朱筱俊,等.分布式连接全装配钢筋混凝土楼盖板缝节点平面内受力性能试验研究[J].建筑结构学报,2019,40(2):178-188.
PANG Rui,LIANG Shuting,ZHU Xiaojun,et al.Experimental study on in-plane mechanical behavior of slab connections of discretely connected precast RC diaphragms[J].Journal of Building Structures,2019,40(2):178-188.
[5]HABER Z B,MACKIE K R,AL-JELAWY H M.Testing and analysis of precast columns with grouted sleeve connections and shifted plastic hinging[J].Journal of Bridge Engineering,2017,22(10):04017078.
[6]LIN C M,CHANG C M,CHEN J H,et al.Microstructure and wear characteristics of high-carbon Cr-based alloy claddings formed by gas tungsten arc welding(GTAW)[J].Surface and Coatings Technology,2010,205(7):2590-2596.
[7]姜 凡,刘文晓,李 淼.基于灌浆套筒连接装配式混凝土柱抗震性能研究[J].混凝土,2020(11):121-124,128.
JIANG Fan,LIU Wenxiao,LI Miao.Study on seismic behavior of assembled concrete columns connected with grouting sleeves[J].Concrete,2020(11):121-124,128.
[8]屈魏超,雷远德.单排套筒和双排套筒连接的装配式钢筋混凝土联肢剪力墙基础隔震结构受力性能对比研究[J].建筑结构,2021,51(增1):980-987.
QU Weichao,LEI Yuande.Studies of mechanical performances of precast concrete coupled shear wall base-isolated structures with single sleeve connection or double sleeve connection [J].Building Structure,2021,51(S1):980-987.
[9]HAN R L,SHI W X,WEI D.Behavior of grout sleeve connections under eccentric cyclic load[J].Advanced Materials Research,2012,368-373:48-52.
[10]HUANG Y,ZHU Z G,NAITO C J,et al.Tensile behavior of half grouted sleeve connections:experimental study and analytical modeling[J].Construction and Building Materials,2017,152:96-104.
[11]张微敬,王桂洁,张晨骋,等.钢筋机械连接的装配式框架抗震性能试验研究与有限元分析[J].土木工程学报,2019,52(5):47-58.
ZHANG Weijing,WANG Guijie,ZHANG Chencheng,et al.Experimental study and finite element analysis on seismic behavior of assembled frames with rebars spliced by mechanical connection[J].China Civil Engineering Journal,2019,52(5):47-58.
[12]李向民,王玉兰,高润东,等.高强钢筋机械连接接头力学性能的试验研究[J].工业建筑,2017,47(12):148-151.
LI Xiangmin,WANG Yulan,GAO Rundong,et al.Experimental research on mechanical properties of mechanical splicing of high strength rebars[J].Industrial Construction,2017,47(12):148-151.
[13]REX C O,EASTERLING W S.Behavior and modeling of single bolt lap-plate connections[J].Steel and Composite Structures,2002,2(4):277-296.
[14]李潇然,赵作周,钱稼茹,等.竖向钢筋混合连接预制剪力墙抗震性能试验[J].哈尔滨工业大学学报,2020,52(10):1-9.
LI Xiaoran,ZHAO Zuozhou,QIAN Jiaru,et al.Experimental studies on seismic performance of precast shear walls with hybrid vertical rebar connections[J].Journal of Harbin Institute of Technology,2020,52(10):1-9.
[15]潘广斌,蔡 健,杨 春,等.冷挤压套筒连接RC装配式剪力墙抗震性能试验研究[J].建筑结构学报,2021,42(5):111-120.
PAN Guangbin,CAI Jian,YANG Chun,et al.Experimental study on seismic behavior of precast RC shear walls connected by extruding steel sleeves and rebars[J].Journal of Building Structures,2021,42(5):111-120.
[16]SHENG X W,ZHENG W Q,YANG Y.Tensile and high-cycle fatigue performance of HRB500 high-strength steel rebars joined by flash butt welding[J].Construction and Building Materials,2020,241:118037.
[17]段留省,张化兵,潘 宏,等.钢板组合单边螺栓钢筋机械连接件抗拉性能试验[J].哈尔滨工业大学学报,2021,53(10):156-163.
DUAN Liusheng,ZHANG Huabing,PAN Hong,et al.Experimental study on tensile properties of steel plate composite blind bolts as rebar mechanical connectors[J].Journal of Harbin Institute of Technology,2021,53(10):156-163.
[18]黄海鹏,迟关心,王振龙.电火花加工数控系统软件数据流控制技术研究[J].制造技术与机床,2018(10):49-52.
HUANG Haipeng,CHI Guanxin,WANG Zhenlong.Control of data stream for EDM CNC system software[J].Manufacturing Technology & Machine Tool,2018(10):49-52.
[19]高 强,赵唯坚.单向拉伸荷载下堆焊成型套筒灌浆连接性能试验研究[J].建筑结构学报,2022,43(4):208-219.
GAO Qiang,ZHAO Weijian.Experimental study on performance of grouted sleeve connection with surfacing forming under uniaxial tensile load[J].Journal of Building Structures,2022,43(4):208-219.

Memo

Memo:
-
Last Update: 2024-09-30