[1] BAILEY C G,LENNON T,MOORE D B.The Behaviour of Full-scale Steel Framed Buildings Subjected to Compartment Fires[J].The Structural Engin-eer,1999,77(8):15-21.
[2]O'CONNER M A,KIRBY B R,MARTIN D M.Behaviour of a Multi-storey Composite Steel Framed Building in Fire[J].The Structural Engineer,2003,81(2):27-36.
[3]PARK R.Tensile Membrane Behaviour of Uniformly Loaded Rectangular Reinforced Concrete Slabs with Full Restrained Edges[J].Magazine of Concrete Research,1964,16(46):39-44.
[4]PARK R.Ultimate Strength of Rectangular Concrete Slabs Under Short-term Uniform Loading with Edges Restrained Against Lateral Movement[J].Proceedings of the Institution of Civil Engineers,1964,28(2):125-150.
[5]SAWCZUK A,WINNICKI L.Plastic Behavior of Simply Supported Reinforced Concrete Plates at Moderately Large Deflections[J].International Journal of Solids and Structures,1965,1(1):97-111.
[6]KEMP K O.Yield of a Square Reinforced Concrete Slab on Simple Supports Allowing for Membrane Forces[J].The Structural Engineer,1967,45(7):235-240.
[7]TAYLOR R A.A Note on a Possible Basis for a New Methodof Ultimate Load Design of Reinforced Concrete Slabs[J].Magazine of Concrete Research,1965,17(53):183-186.
[8]MORLEY C T.Yield Line Theory for Reinforced Concrete Slabs at Moderately Large Deflections[J].Magazine of Concrete Research,1967,19(66):212-222.
[9]TAYLOR R,MAHER D R H,HAYES B.Effect of the Arrangement of Re-inforcement on the Behavior of Reinforced Concrete Slabs[J].Magazine of Concrete Research,1966,18(55):85-94.
[10]JANAS M.Large Plastic Deformations of Reinforced Concrete Slabs[J].International Journal of Solids Structures,1968,4(1):61-74.
[11]BAILEY C G.Membrane Action of Unrestrained Lightly Reinforced Concrete Slabs at Large Displacement[J].Engineering Structures,2001,23(5):470-483.
[12]FOSTER S J,BAILEY C G,BURGESS I W,et al.Experimental Behaviour of Concrete Floor Slabs at Large Displacements[J].Engineering Structures,2004,26(9):1231-1247.
[13]BAILEY C G,TOH W S.Small-scale Concrete Slab Tests at Ambient and Elevated Temperatures[J].En-gineering Structures,2007,29(10):2775-2791.
[14]BAILEY C G,WHITE D S,MOORE D B.The Tensile Membrane Action of Unrestrained Composite Slabs Simulated Under Fire Conditions[J].Engineering Structures,2000,22(12):1583-1595.
[15]BAILEY C G,TOH W S.Behaviour of Concrete Floor Slabs at Ambient and Elevated Temperatures[J].Fire Safety Journal,2007,42(6/7):425-436.
[16]CAMERON N J K,USMANI A S.New Design Method to Determine the Membrane Capacity of Laterally Restrained Composite Floor Slabs in Fire.Part 1:Theory and method[J].The Structural Engineer,2005,83(19):28-33.
[17]DONG Y L,FANG Y Y.Determination of Tensile Membrane Effects by Segment Equilibrium[J].Magazine of Concrete Research,2009,61(12):1-7.
[1]魏巍巍,贡金鑫,田磊.钢筋混凝土板受冲切承载力对比分析[J].建筑科学与工程学报,2010,27(04):44.
WEI Wei-wei,GONG Jin-xin,TIAN Lei.Comparative Analysis of Punching Shear Capacity for
Reinforced Concrete Slabs[J].Journal of Architecture and Civil Engineering,2010,27(04):44.