|本期目录/Table of Contents|

[1]魏巍巍,贡金鑫,田磊.钢筋混凝土板受冲切承载力对比分析[J].建筑科学与工程学报,2010,27(04):44-56.
 WEI Wei-wei,GONG Jin-xin,TIAN Lei.Comparative Analysis of Punching Shear Capacity for Reinforced Concrete Slabs[J].Journal of Architecture and Civil Engineering,2010,27(04):44-56.
点击复制

钢筋混凝土板受冲切承载力对比分析(PDF)
分享到:

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

卷:
27卷
期数:
2010年04期
页码:
44-56
栏目:
出版日期:
2010-12-20

文章信息/Info

Title:
Comparative Analysis of Punching Shear Capacity for Reinforced Concrete Slabs
作者:
魏巍巍1,贡金鑫1,田磊1,2
1. 大连理工大学 建设工程学部,辽宁 大连 116024; 2. 中交水运规划设计院有限公司,北京 100007
Author(s):
WEI Wei-wei1, GONG Jin-xin1, TIAN Lei1,2
1. Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, Liaoning, China; 2. China Communications Water Transportation Planning and Design Institute Co. Ltd, Beijing 100007, China
关键词:
钢筋混凝土板 受冲切承载力 规范 配筋率 不平衡弯矩
Keywords:
reinforced concrete slab punching shear capacity code reinforcement ratio unbalanced moment
分类号:
TU375.2
DOI:
-
文献标志码:
A
摘要:
对中国规范GB 50010—2002、美国规范ACI 318-08和欧洲规范EN 1992-1-1:2004中钢筋混凝土柱支撑板在无不平衡弯矩和有不平衡弯矩作用下的受冲切承载力计算方法进行了对比,研究了影响受冲切承载力的因素,并给出了不平衡弯矩作用下等效设计剪力系数的简化计算公式。结果表明:中国和美国规范板受冲切承载力计算体系较为接近,但欧洲规范计算体系与中国、美国规范相比差别较大; 无不平衡弯矩作用时混凝土强度、板有效高度、柱边长比、抗冲切钢筋等因素对受冲切承载力影响较大; 有不平衡弯矩作用时受冲切承载力计算还取决于不平衡弯矩; 推导得到的中国、美国和欧洲规范中柱的等效设计剪力系数公式比较接近,即中国、美国和欧洲规范中的不平衡弯矩系数是接近的。
Abstract:
Prediction models of punching shear capacity for reinforced concrete slabs with or without unbalanced moment based on GB 50010—2002, ACI 318-08 and EN 1992-1-1:2004 were compared and analyzed. Then, the factors influencing punching shear capacity were researched. Finally, simplified calculation formulas of equivalent design shear coefficients under unbalanced moment were derived. Results show that prediction models of punching shear capacity based on Chinese code are close to those of American code, but different from those of Eurocode. The effects of concrete strength, effective depth of slabs, side ratio of column and punching resistance reinforcements on punching shear capacity without unbalanced moment are significant. In addition to these factors, unbalanced moment has influence on punching shear capacity with unbalanced moment. Furthermore, the derived formulas of equivalent design shear coefficients for interior column based on three codes are close to each other, and unbalanced moment coefficients based on three codes are close to each other.

参考文献/References:

[1] 贡金鑫,魏巍巍,胡家顺.中美欧混凝土结构设计[M].北京:中国建筑工业出版社,2007. GONG Jin-xin,WEI Wei-wei,HU Jia-shun.Design of Concrete Structure Based on Chinese,American and European Codes[M].Beijing:China Architecture & Building Press,2007.
[2]REGAN P E,BRAESTRUP M W.Punching Shear in Reinforced Concrete[R].Lausanne:Comite Euro-International,1985.
[3]ALEXANDER S D B,SIMMONDS S H.Ultimate Strength of Slab-column Connections[J].ACI Structure Journal,1987,84(3):255-261.
[4]BAZANT Z P,CAO Z.Size Effect in Punching Shear Failure of Slabs[J].ACI Structure Journal,1987,84(1):44-53.
[5]GONZALEZ-VIDOSA F,KOTSOVOS M D,PAVLOVIC M N.Symmetrical Punching of Reinforced Concrete Slabs:an Analytical Investigation Based on Nonlinear Finite Element Modeling[J].ACI Structure Journal,1988,85(3):241-250.
[6]HALLGREN M.Punching Shear Capacity of Reinforced High Strength Concrete Slabs[D].Stockholm:Royal Institute of Technology,1996.
[7]THEODORAKOPOULOS D D,SWAMY R N.Ultimate Punching Shear Strength Analysis of Slab-column Connections[J].Cement & Concrete Composites,2002,24(6):509-521.
[8]GB 50010—2002,混凝土结构设计规范[S]. GB 50010—2002,Code for Design of Concrete Structures[S].
[9]ACI 318-08,Building Code Requirements for Structural Concrete(ACI 318-08)and Commentary[S].
[10]EN 1992-1-1:2004,Eurocode 2:Design of Concrete Structures.Part 1-1:General Rules and Rules for Buildings[S].
[11]刘立渠.国内外规范关于钢筋混凝土板冲切承载力的比较研究[J].建筑结构,2007,37(7):46-50. LIU Li-qu.Discussion on Calculating Punching Shear Strength of Reinforced Concrete Slabs and Footings According to Different Codes[J].Building Structure,2007,37(7):46-50.
[12]魏巍巍,贡金鑫,田 磊.钢筋混凝土构件受剪承载力对比分析[J].建筑科学与工程学报,2010,27(2):25-37. WEI Wei-wei,GONG Jin-xin,TIAN Lei.Comparative Analysis of Shear Capacity for Reinforced Concrete Members[J].Journal of Architecture and Civil Engineering,2010,27(2):25-37.
[13]张建仁,张克波,彭 晖,等.锈蚀钢筋混凝土矩形梁正截面抗弯承载力计算方法[J].中国公路学报,2009,22(3):45-51. ZHANG Jian-ren,ZHANG Ke-bo,PENG Hui,et al.Calculation Method of Normal Section Flexural Capacity of Corroded Reinforced Concrete Rectangular Beams[J].China Journal of Highway and Transport,2009,22(3):45-51.
[14]王建超,赵君黎,贡金鑫,等.钢-混凝土组合桥梁承载力可靠度分析[J].中国公路学报,2009,22(3):76-82. WANG Jian-chao,ZHAO Jun-li,GONG Jin-xin,et al.Bearing Capacity Reliability Analysis of Steel-concrete Composite Bridge[J].China Journalof Highway and Transport,2009,22(3):76-82.
[15]刘小燕,颜东煌,张 峰,等.预应力高强混凝土梁极限承载力分析[J].中国公路学报,2006,19(1):58-61,79. LIU Xiao-yan,YAN Dong-huang,ZHANG Feng,et al.Ultimate Load Analysis of Prestressed High-strength Concrete Beam[J].China Journal of Highway and Transport,2006,19(1):58-61,79.
[16]张建仁,王 磊.既有钢筋混凝土桥梁构件承载力估算方法[J].中国公路学报,2006,19(2):49-55. ZHANG Jian-ren,WANG Lei.Estimated Approach to Carrying Capacity of Existing Reinforced Concrete Bridge Member[J].China Journal of Highway and Transport,2006,19(2):49-55.
[17]徐爱敏,陈衡治,谢 旭.结构极限承载力计算方法及其收敛性[J].中国公路学报,2006,19(5):65-70. XU Ai-min,CHEN Heng-zhi,XIE Xu.Calculation Method for Ultimate Bearing Capacity of Structure and Its Convergence[J].China Journal of Highway and Transport,2006,19(5):65-70.
[18]赵灿晖.上承式钢桁拱桥面内极限承载力分析[J].交通运输工程学报,2007,7(6):80-85. ZHAO Can-hui.In-plane Ultimate Bearing Capacity Analysis of Deck-type Steel Braced Arch Bridge[J].Journal of Traffic and Transportation Engineering,2007,7(6):80-85.

相似文献/References:

[1]董毓利.火灾时钢筋混凝土板的承载力计算[J].建筑科学与工程学报,2009,26(04):14.
 DONG Yu-li.Calculation of Bearing Capacity of RC Concrete Slabs in Fire[J].Journal of Architecture and Civil Engineering,2009,26(04):14.

备注/Memo

备注/Memo:
收稿日期:2010-09-19
基金项目:“十一五”国家科技支撑计划项目(2006BAJ01B06-06)
作者简介:魏巍巍(1982-),女,辽宁锦州人,工学博士研究生,E-mail:3134586weiweiwei@gmail.com。
更新日期/Last Update: 2010-12-20