[1] 叶列平,冯 鹏.FRP在工程结构中的应用与发展[J].土木工程学报,2006,39(3):24-36.YE Lie-ping,FENG Peng.Applications and Development of Fiber-reinforced Polymer in Engineering Structures[J].China Civil Engineering Journal,2006,39(3):24-36.
[2]ACMA.Global FRP Use in Bridge Applications[R].New York:ACMA,2004.
[3]冯 鹏,叶列平,金飞飞,等.FRP桥梁结构的受力性能与设计方法[J].工业建筑,2009,39(增):23-30.FENG Peng,YE Lie-ping,JIN Fei-fei,et al.Mechan-ical Behaviors and Design Methods of FRP Bridge Structures[J].Industrial Construction,2009,39(S):23-30.
[4]汤国栋.玻璃钢斜拉桥研究与实践[J].重庆交通学院学报,1987,16(3):1-12.TANG Guo-dong.The Analytical and Experimental Work of GRP Cable-stayed Pedestrian Bridge[J].Journal of Chongqing Jiaotong University,1987,16(3):1-12.
[5]吕志涛,梅葵花.国内首座CFRP索斜拉桥的研究[J].土木工程学报,2007,40(1):54-59.LU Zhi-tao,MEI Kui-hua.First Application of CFRP Cables for a Cable-stayed Bridge in China[J].China Civil Engineering Journal,2007,40(1):54-59.
[6]冯 鹏.新型FRP空心桥面板的设计开发与受力性能研究[D].北京:清华大学,2004.FENG Peng.Development and Study on an Innovative FRP Bridge Deck[D].Beijing:Tsinghua University,2004.
[7]冯 鹏,叶列平.外部纤维缠绕增强FRP桥面板受力性能试验研究[J].土木工程学报,2009,42(9):61-67.FENG Peng,YE Lie-ping.Experimental Study on Exterior Filament-wound Strengthening Fiber-reinforced Polymer Bridge Decks[J].China Civil Engineering Journal,2009,42(9):61-67.
[8]朱坤宁,万 水,刘玉擎.FRP桥面板静载试验研究及分析[J].工程力学,2009,26(增2):618-622.ZHU Kun-ning,WAN Shui,LIU Yu-qing.Analysis and Experimental Study on Statically Loaded FRP Bridge Deck[J].Engineering Mechanics,2009,26(S2):618-622.
[9]李天虹.FRP-混凝土组合梁受力性能和设计方法研究[D].北京:清华大学,2007.LI Tian-hong.Study on Mechanical Performance and Design Method of FRP-concrete Hybrid Beams [D].Beijing:Tsinghua University,2007.
[10]王言磊.FRP-混凝土组合梁/桥面结构试验、分析与设计方法[D].哈尔滨:哈尔滨工业大学,2008.WANG Yan-lei.Experimental Investigation,Analysis and Design Methods for FRP-concrete Composite Beam/Bridge Superstructure Systems[D].Harbin:Harbin Institute of Technology,2008.
[11]谢 旭,朱越峰.CFRP拉索设计对大跨度斜拉桥力学特性的影响[J].工程力学,2007,24(11):113-120.XIE Xu,ZHU Yue-feng.Study on Behavior of Long-span CFRP Cable-stayed Bridges[J].Engineering Mechanics,2007,24(11):113-120.
[12]FENG P,YE L P,TENG J G.Large-span Woven Web Structure Made of Fiber-reinforced Polymer [J].Journal of Composites for Construction,2007,11(2):110-119.
[13]ZIVANOVIC S,PAVIC A,REYNOLDS P.Vibration Serviceability of Footbridges Under Human-induced Excitation:a Literature Review[J].Journal of Sound and Vibration,2005,279(1/2):1-74.
[14]陈政清,华旭刚.人行天桥的振动与动力设计[M].北京:人民交通出版社,2009.CHEN Zheng-qing,HUA Xu-gang.Vibration and Dynamics Design of Footbridge[M].Beijing:China Communications Press,2009.
[15]CJJ 69—95,城市人行天桥与人行地道技术规范[S].CJJ 69—95,Technical Specifications of Urban Pedestrain Overcrossing and Underpass[S].
[16]SNIP 2.05.03-84,Construction Regulation.Bridges and Pipes[S].
[17]AASHTO-2004,LRED Bridge Design Specifications[S].
[18]AASHTO-2008,Guide Specifications for Design of FRP Pedestrian Bridges[S].
[19]CAN/CSA-S6-00,Canadian Highway Bridge Design Code[S].
[20]BS EN 1990:2002,Eurocode:Basis of Structural Design[S].
[21]ZHOU A,BAI Y,KELLER T.Dynamic Characteristics of Bridge Superstructures with FRP Composite Structural Elements[C]//HAMELIN P.Proceedings of the Third International Conference on Composites in Constructions.Lyon:ICCC,2005:971-978.
[22]FUJINO Y,PACHECO B M,NAKAMURA S,et al.Synchronization of Human Walking Observed During Lateral Vibration of a Congested Pedestrian Bridge[J].Earthquake Engineering & Structural Dynamics,1993,22(9):741-758.
[23]BS 5400-2:1978,Steel,Concrete and Composite Bridges—Part 2:Specification for Loads[S].
[24]WHEELER J E.Prediction and Control of Pedestrian-induced Vibration in Footbridge [J].Journal of Structural Division,1982,108(9):2045-2065.
[25]何 勇,金伟良,宋志刚.多跨人行天桥振动均方根加速度响应谱法[J].浙江大学学报:工学版,2008,42(1):48-53.HE Yong,JIN Wei-liang,SONG Zhi-gang.RMS Acceleration Response Spectrum Method of Multi-span Footbridge Under Pedestrian Excitation[J].Journal of Zhejiang University:Engineering Science,2008,42(1):48-53.
[26]KERR S C,BISHOP N W M.Human Induced Loading on Flexible Staircases[J].Engineering Structures,2001,23(1):37-45.
[27]ELLINGWOOD B,TALLIN A.Structural Serviceability:Floor Vibrations[J].Journal of Structural Engineering,1984,110(2):401-418.
[28]BACHMANN H.Vibration Upgrading of Gymnasia,Dance Halls and Footbridges[J].Structural Engineering International,1992,2(2):118-124.
[29]ANDRIACCHI T P,OGLE J A,GALANTE J O.Walking Speed as a Basis for Normal and Abnormal Gait Measurements[J].Journal of Biomechanics,1977,10(4):261-268.
[30]CAETANO E,CUNHA A,HOORPAH W,et al.Footbridge Vibration Design[M].Boca Raton:CRC Press,2009.
[31]CHANDRA R,SINGH S P,GUPTA K.Damping Studies in Fiber-reinforced Composites:a Review[J].Composite Structures,1999,46(1):41-51.
[32]ALURI S,JINKA C,GANGARAO H V S.Dynamic Response of Three Fiber Reinforced Polymer Composite Bridges[J].Journal of Bridge Engineering,2005,10(6):722-730.
[33]BAI Y,KELLER T.Modal Parameter Indentification for a GFRP Pedestrian Bridge[J].Composite Structures,2008,82(1):90-100.