[1]王蕴哲,周天华,吴函恒,等.冷弯型钢“框-墙”复合结构墙体上下层间受力性能研究[J].建筑科学与工程学报,2024,41(04):31-41.[doi:10.19815/j.jace.2022.08011]
 WANG Yunzhe,ZHOU Tianhua,WU Hanheng,et al.Research on inter-story mechanical behavior of cold-formed steel “frame-wall” composite structure wall[J].Journal of Architecture and Civil Engineering,2024,41(04):31-41.[doi:10.19815/j.jace.2022.08011]
点击复制

冷弯型钢“框-墙”复合结构墙体上下层间受力性能研究(PDF)
分享到:

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

卷:
41卷
期数:
2024年04期
页码:
31-41
栏目:
建筑结构
出版日期:
2024-07-19

文章信息/Info

Title:
Research on inter-story mechanical behavior of cold-formed steel “frame-wall” composite structure wall
文章编号:
1673-2049(2024)04-0031-11
作者:
王蕴哲,周天华,吴函恒,隋 璐,王继琴,王帅兵
(长安大学 建筑工程学院,陕西 西安 710061)
Author(s):
WANG Yunzhe, ZHOU Tianhua, WU Hanheng, SUI Lu, WANG Jiqin, WANG Shuaibing
(School of Civil Engineering, Chang'an University, Xi'an 710061, Shaanxi, China)
关键词:
冷弯型钢组合墙体 双层墙体 拟静力试验 层间受力性能 数值分析
Keywords:
cold-formed steel frame wall double-story wall pseudo-static test mechanical behavior of inter-story numerical analysis
分类号:
TU392.5
DOI:
10.19815/j.jace.2022.08011
文献标志码:
A
摘要:
提出了一种新型的冷弯型钢“框-墙”复合结构墙体,并对2片不同层数的足尺墙体试件进行了拟静力试验。依据破坏形态、滞回曲线、骨架曲线、位移延性系数等性能指标,与单层墙体对比,重点考察双层墙体上下层间的受力性能。此外,基于ABAQUS有限元分析软件对双层墙体的滞回性能进行模拟,并对层间连接部位的层间边框梁屈服强度、层间抗拔螺栓间距和高宽比进行参数分析。结果表明:试验全程双层墙体上下层间螺栓连接无明显滑移与拔起,具有半刚性特征,且根据位移计实测结果,墙体上下层间位移趋近于0; 在考虑了上下层间连接部位后,双层墙体的位移延性系数和峰值荷载较单层墙体分别降低了1.84%和8.33%,说明冷弯型钢“框-墙”复合结构墙体上下层间传力、连接性较好; 层间边框梁屈服强度和层间抗拔螺栓间距对墙体的抗剪承载力和抗侧刚度影响较小,而高宽比对双层墙体的抗侧刚度和抗剪承载力影响较大; 研究成果可为该类墙体应用于多层冷弯型钢房屋住宅提供参考。
Abstract:
A new type of cold-formed steel “frame-wall” composite structure was proposed, and pseudo-static tests were carried out on two full-scale wall specimens with different layers. According to the performance indexes such as failure mode, hysteretic curve, skeleton curve and displacement ductility coefficient, compared with single-story wall, the mechanical performance of inter-story of double-story wall was mainly investigated. In addition, based on ABAQUS finite element analysis software, the hysteresis performance of the double-story wall was simulated, and the yield strength of the inter-story edge beam, the spacing of the inter-story pullout bolts and the aspect ratio were analyzed. The results show that the bolt connection of double-story wall's inter-story has no obvious slip and pull-up, and has semi-rigid characteristics. According to the displacement meter measurement, the inter-story displacement tends to 0. Compared with the single-story specimen, after considering the connection of inter-story, the ductility and shear capacity of the double-story specimen decrease by 1.84% and 8.33% respectively, indicating that the force transfer of inter-story and the integrality of the walls performs well. The yield strength of the inter-story edge beam and the spacing of the inter-story pullout bolts have little effect on the shear capacity and lateral stiffness of the wall, while the aspect ratio has a great influence on the lateral stiffness and shear capacity of the double-story wall. The research findings can provide a reference for the design of multi-story cold-formed steel residence.

参考文献/References:

[1] 周绪红,石 宇,周天华,等.低层冷弯薄壁型钢结构住宅体系[J].建筑科学与工程学报,2005,22(2):1-14.
ZHOU Xuhong,SHI Yu,ZHOU Tianhua,et al.Cold-formed steel framing system of low-rise residential building[J].Journal of Architecture and Civil Engineering,2005,22(2):1-14.
[2]周绪红,石 宇,周天华,等.冷弯薄壁型钢结构住宅组合墙体受剪性能研究[J].建筑结构学报,2006,27(3):42-47.
ZHOU Xuhong,SHI Yu,ZHOU Tianhua,et al.Study on shear resistance of cold-formed steel stud walls in residential structures[J].Journal of Building Structures,2006,27(3):42-47.
[3]PETERMAN K D,SCHAFER B W.Sheathed cold-formed steel studs under axial and lateral load[J].Journal of Structural Engineering,2014,140(10):04014074.
[4]周天华,吴函恒,蒋 路,等.夹芯钢板冷弯型钢组合墙体抗剪性能试验研究[J].土木工程学报,2012,45(11):22-28.
ZHOU Tianhua,WU Hanheng,JIANG Lu,et al.Experimental study on the shearing performance of sandwich board cold-formed steel composite wall[J].China Civil Engineering Journal,2012,45(11):22-28.
[5]BADR A R,ELANWAR H H,MOURAD S A.Numerical and experimental investigation on cold-formed walls sheathed by fiber cement board[J].Journal of Constructional Steel Research,2019,158:366-380.
[6]WANG X X,WANG W,LI Y C.Cyclic performance of K-braced cold-formed steel shear walls with concrete-filled steel-tubular struts[J].Journal of Constructional Steel Research,2020,173:106249.
[7]吴函恒,晁思思,刘向斌,等.轻质脱硫石膏改性材料填充冷弯型钢组合墙体抗震性能试验研究[J].建筑结构学报,2020,41(1):42-50.
WU Hanheng,CHAO Sisi,LIU Xiangbin,et al.Experimental study on seismic behavior of cold-formed steel framing walls infilled with lightweight modified FGD gypsum[J].Journal of Building Structures,2020,41(1):42-50.
[8]王春刚,李禹东,张壮南,等.角撑加强型冷弯薄壁型钢组合墙体受剪性能试验研究[J].建筑结构学报,2020,41(增2):291-303.
WANG Chungang,LI Yudong,ZHANG Zhuangnan,et al.Experimental study on shear behavior of corner brace reinforced cold-formed thin-walled steel composite wall[J].Journal of Building Structures,2020,41(S2):291-303.
[9]管 宇,周绪红,石 宇,等.多层冷弯薄壁型钢结构住宅水平荷载分配关系研究[J].建筑结构学报,2023,40(1):143-153.
GUAN Yu,ZHOU Xuhong,SHI Yu,et al.Research on horizontal load distribution relationship of multi-storey cold-formed thin-walled steel residential buildings[J].Journal of Building Structures,2023,40(1):143-153.
[10]李元齐,刘 飞,沈祖炎,等.高强超薄壁冷弯型钢低层住宅足尺模型振动台试验[J].建筑结构学报,2013,34(1):36-43.
LI Yuanqi,LIU Fei,SHEN Zuyan,et al.Shaking table test on a full-scale model of low-rise high-strength cold-formed thin-walled steel framing buildings[J].Journal of Building Structures,2013,34(1):36-43.
[11]黄智光,苏明周,何保康,等.冷弯薄壁型钢三层房屋振动台试验研究[J].土木工程学报,2011,44(2):72-81.
HUANG Zhiguang,SU Mingzhou,HE Baokang,et al.Shaking table test on seismic behaviors of three-story cold-formed thin-wall steel residential buildings[J].China Civil Engineering Journal,2011,44(2):72-81.
[12]褚云朋,王秀丽,姚 勇.冷弯薄壁型钢双层组合墙体抗剪性能试验研究[J].工程科学与技术,2019,51(2):45-52,70.
CHU Yunpeng,WANG Xiuli,YAO Yong.Shearing experiments of cold-formed steel thin-wall panels under cyclic load[J].Advanced Engineering Sciences,2019,51(2):45-52,70.
[13]王志军,陈兴杰,石 宇,等.轻钢龙骨复合墙体层间连接受剪性能试验研究[J].建筑结构学报,2021,42(11):83-96.
WANG Zhijun,CHEN Xingjie,SHI Yu,et al.Experimental study on shear performance of inter-story connection of light gauge steel composite walls[J].Journal of Building Structures,2021,42(11):83-96.
[14]ZOU Y X,ZHOU X H,SHI Y,et al.Shear resistance of cold-formed thin-walled steel inter-story connections[J].Journal of Constructional Steel Research,2021,183:106757.
[15]周天华,王继琴,邵英豪,等.弱框架-轻钢复合墙体装配式房屋结构体系[J].建筑科学与工程学报,2022,39(1):36-43.
ZHOU Tianhua,WANG Jiqin,SHAO Yinghao,et al.Prefabricated building structural system of weak frame-light steel composite wall[J].Journal of Architecture and Civil Engineering,2022,39(1):36-43.
[16]低层冷弯薄壁型钢房屋建筑技术规程:JGJ 227—2011[S].北京:中国建筑工业出版社,2011.
Technical specification for low-rise cold-formed thin-walled steel buildings:JGJ 227—2011[S].Beijing:China Architecture & Building Press,2011.
[17]金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2021[S].北京:中国标准出版社,2021.
Metallic materials — tensile testing — part 1:method of test at room temperature:GB/T 228.1—2021[S].Beijing:Standards Press of China,2021.
[18]建筑抗震试验规程:JGJ/T 101—2015[S].北京:中国建筑工业出版社,2015.
Specification for seismic test of buildings:JGJ/T 101—2015[S].Beijing:China Architecture & Building Press,2015.
[19]建筑抗震设计规范:GB 50011—2010[S].北京:中国建筑工业出版社,2010.
Code for seismic design of buildings:GB 50011—2010[S].Beijing:China Architecture & Building Press,2010.
[20]王静峰,胡培芳,汪皖黔,等.装配式混凝土框架-冷弯薄壁型钢复合墙板结构抗震性能试验研究[J].建筑结构学报,2023,44(4):247-256.
WANG Jingfeng,HU Peifang,WANG Wanqian,et al.Experimental study on seismic performance of prefabricated concrete frame-cold-formed thin-walled steel composite wall structures[J].Journal of Building Structures,2023,44(4):247-256.
[21]邓 锐.带斜撑冷弯薄壁型钢墙体抗震性能研究[D].重庆:重庆大学,2019.
DENG Rui.Study on seismic behavior cold-formed thin-walled steel walls with diagonal braces[D].Chongqing:Chongqing University,2019.
[22]LENG J,SCHAFER B W,BUNOPANE S G.Modeling the seismic response of cold-formed steel framed buildings:model development for the CFS-NEES building[C]//SSRC.Proceedings of the Annual Stability Conference Structural Stability Research Council.St.Louis:SSRC,2013,1-17.

相似文献/References:

[1]袁涛涛,隋 璐,吴函恒,等.钢带加强螺钉孔型冷弯型钢组合墙体抗震性能[J].建筑科学与工程学报,2021,38(03):43.[doi:10.19815/j.jace.2020.07001]
 YUAN Tao-tao,SUI Lu,WU Han-heng,et al.Seismic Behavior of Cold-formed Steel Framing Walls with Strengthened Steel Strips in Screw Holes[J].Journal of Architecture and Civil Engineering,2021,38(04):43.[doi:10.19815/j.jace.2020.07001]

备注/Memo

备注/Memo:
收稿日期:2023-08-05
基金项目:陕西省重点研发计划项目(2019SF-239)
通信作者:周天华(1963-),男,工学博士,教授,博士生导师,E-mail:zhouth@chd.edu.cn。
更新日期/Last Update: 2024-07-20