|本期目录/Table of Contents|

[1]陈扬,刘钊.节段预制箱梁后浇横隔墙的水化热效应分析[J].建筑科学与工程学报,2012,29(01):110-114.
 CHEN Yang,LIU Zhao.Analysis of Hydration Heat Effect Due to Post-casting Diaphragm in Segmental Precast Box-girder[J].Journal of Architecture and Civil Engineering,2012,29(01):110-114.
点击复制

节段预制箱梁后浇横隔墙的水化热效应分析(PDF)
分享到:

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

卷:
29卷
期数:
2012年01期
页码:
110-114
栏目:
出版日期:
2012-03-30

文章信息/Info

Title:
Analysis of Hydration Heat Effect Due to Post-casting Diaphragm in Segmental Precast Box-girder
作者:
陈扬,刘钊
东南大学 土木工程学院,江苏 南京 210096
Author(s):
CHEN Yang, LIU Zhao
School of Civil Engineering, Southeast University, Nanjing 210096, Jiangsu, China
关键词:
水化热效应 温度场 应力场 有限元 预制箱梁 后浇横隔墙
Keywords:
hydration heat effect temperature field stress field finite element prefabricated box-girder post-casting diaphragm
分类号:
U443.22
DOI:
-
文献标志码:
A
摘要:
结合某实桥工程背景,对节段预制箱梁进行后浇横隔墙施工过程的水化热效应进行了研究,使用有限元软件ANSYS建模,根据三维瞬态温度场理论,进行了水化热效应的仿真模拟,分析了箱体温度场和应力场的分布及随时间变化情况,揭示了水化热温度应力使预制箱体腹板外表面受拉、内侧受压的规律及峰值拉应力区域,指出容易开裂的位置; 分析了水泥品种、混合材料用量、入模温度3个参数对应力场的影响规律及影响程度。结果表明:水泥品种对水化热效应的影响最大,其次是混合材料用量的影响,入模温度对水化热效应的影响最小。
Abstract:
Hydration heat effect induced by construction of post-casting diaphragm in segmental precast box-girder was studied combining with practical engineering. The model was founded with finite element software ANSYS. Based on the theory of three-dimensional transient temperature field, the hydration heat effect was simulated. The distribution and variation with time of the temperature field and the stress field of box-girder were analyzed. The law that the outer of web was under tension and the inner of web was under compression due to thermal stress caused by hydration heat, and the region of peak value of tensile stress were reveled, and the easy crack position was pointed out. The influences of laws and degrees of cement varieties, admixture proportions and casting temperatures on stress field were analyzed. The results show that the influence of cement variety on hydration heat effect is greatest, that of admixture proportion is the greater, and that of casting temperature is the smallest.

参考文献/References:

[1] 楼庄鸿.大跨径梁式桥的主要病害[J].公路交通科技,2006,23(4):84-87. LOU Zhuang-hong.Main Faults in Large Span Beam Bridges[J].Journal of Highway and Transportation Research and Development,2006,23(4):84-87.
[2]臧 华,刘 钊,文武松,等.苏通大桥辅桥箱梁节段水化热效应的仿真分析[J].公路交通科技,2007,24(5):95-98. ZANG Hua,LIU Zhao,WEN Wu-song,et al.Simulation of Hydration Heat Effects on the Box Girder Segments of the Auxiliary Bridge for Sutong Bridge[J].Journal of Highway and Transportation Research and Development,2007,24(5):95-98.
[3]朱伯芳.大体积混凝土温度应力及温度控制[M].北京:中国电力出版社,1999. ZHU Bo-fang.Mass Concrete Temperature Stress and Temperature Control[M].Beijing:China Electric Power Press,1999.
[4]李 东,潘育耕.混凝土水化热瞬态温度场数值计算过程中的水化放热规律及水化速率问题[J].西安建筑科技大学学报:自然科学版,1999,31(3):277-279. LI Dong,PAN Yu-geng.Law and Velocity of Hydro-thermo Dissipation in the Calculation of Concrete Transient Temperature Field[J].Journal of Xi'an University of Architecture & Technology:Natural Science Edition,1999,31(3):277-279.
[5]施惠生,黄小亚.水泥混凝土水化热的研究与进展[J].水泥技术,2009(6):21-26. SHI Hui-sheng,HUANG Xiao-ya.Research Progress of Hydration Heat in Cement and Concrete[J].Cement Technology,2009(6):21-26.
[6]刘 钊,王景全.深圳湾公路大桥非通航孔桥墩顶横隔墙水化热不利效应及其对策研究[R].南京:东南大学,2006. LIU Zhao,WANG Jing-quan.Hydration Heat Effect and Countermeasures for the Diaphragm Wall of Pier-table Segment in Shenzhen Bay Non-navigable Bridge[R].Nanjing:Southeast University,2006.
[7]张学钢.大体积混凝土芯部温度监测及力学性能变化[J].筑路机械与施工机械化,2011,28(5):74-77. ZHANG Xue-gang.Temperature Monitoring and Mechanical Property Change of Core of Mass Concrete[J].Road Machinery & Construction Mechanization,2011,28(5):74-77.
[8]王成军.承台混凝土施工温度控制措施[J].筑路机械与施工机械化,2009,26(5):65-66,72. WANG Cheng-jun.Temperature Control Measure for Construction of Bearing Platform Concrete[J].Road Machinery & Construction Mechanization,2009,26(5):65-66,72.
[9]张 岗,贺拴海,宋一凡.混凝土箱梁水化热温度损伤修正耦合方法[J].交通运输工程学报,2008,8(1):54-60. ZHANG Gang,HE Shuan-hai,SONG Yi-fan.Updating Coupling Method of Hydration Heat Temperature Damage for Concrete Box Girder[J].Journal of Traffic and Transportation Engineering,2008,8(1):54-60.
[10]彭友松,强士中.公路混凝土箱梁三维温度应力计算方法[J].交通运输工程学报,2007,7(1):63-67. Peng You-song,Qiang Shi-zhong.3-D Thermal Stress Computation Method of Highway Concrete Box-girder[J].Journal of Traffic and Transportation En-gineering,2007,7(1):63-67.
[11]邵旭东,占雪芳,金晓勤,等.带地梁的新型半整体式无缝桥梁温度效应研究[J].中国公路学报,2010,23(1):43-48. SHAO Xu-dong,ZHAN Xue-fang,JIN Xiao-qin,et al.Temperature Effect of Innovative Semi-integral Abutment Jointless Bridge with Ground Beam[J].China Journal of Highway and Transport,2010,23(1):43-48.
[12]李潘武,曾宪哲,李博渊,等.浇筑温度对大体积混凝土温度应力的影响[J].长安大学学报:自然科学版,2011,31(5):68-71. LI Pan-wu,ZENG Xian-zhe,LI Bo-yuan,et al.Influence of Placement Temperature on Mass Concrete Temperature Stress[J].Journal of Chang'an University:Natural Science Edition,2011,31(5):68-71.

相似文献/References:

[1]俞明德,沈锐利,唐茂林,等.西堠门大桥主缆横断面温度场研究[J].建筑科学与工程学报,2010,27(03):53.
 YU Ming-de,SHEN Rui-li,TANG Mao-lin,et al.Research on Temperature Field of Main Cable Section of Xihoumen Bridge[J].Journal of Architecture and Civil Engineering,2010,27(01):53.
[2]余志武,唐国庆,丁发兴,等.三面受火钢筋混凝土梁温度场非线性分析[J].建筑科学与工程学报,2005,22(04):11.
 YU Zhi-wu,TANG Guo-qing,DING Fa-xing.Nonlinear analysis of temperature field of reinforced concrete beam with three surfaces exposing to fire[J].Journal of Architecture and Civil Engineering,2005,22(01):11.
[3]刘艳芝,邓集钱,谭清华.内嵌十字型钢的方形劲性不锈钢管混凝土柱 耐火性能[J].建筑科学与工程学报,2019,36(03):66.
 LIU Yan-zhi,DENG Ji-qian,TAN Qing-hua.Fire Resistance of Square Steel Reinforced Concrete-filled Stainless Steel Tube Columns Embedded with Cross-section Steel[J].Journal of Architecture and Civil Engineering,2019,36(01):66.
[4]王 莹,王 盼.油罐车火灾下大跨径双层钢桁梁悬索桥高温 力学性能[J].建筑科学与工程学报,2019,36(03):91.
 WANG Ying,WANG Pan.High Temperature Mechanical Properties of Long-span Double-deck Steel Truss Beam Suspension Bridge Under Tanker Fire[J].Journal of Architecture and Civil Engineering,2019,36(01):91.
[5]吴永哲,朱泽萱,杨 平,等.60 m级超长联络通道冻结法施工与实测分析[J].建筑科学与工程学报,2023,40(06):148.[doi:10.19815/j.jace.2021.11039]
 WU Yongzhe,ZHU Zexuan,YANG Ping,et al.Construction and measurement analysis of freezing method for 60 m level super long connecting passage[J].Journal of Architecture and Civil Engineering,2023,40(01):148.[doi:10.19815/j.jace.2021.11039]
[6]杨青天,多 飞,张晋川,等.火灾下双钢管混凝土复合短柱的性能与承载力计算方法[J].建筑科学与工程学报,2024,41(01):128.[doi:10.19815/j.jace.2022.03101]
 YANG Qingtian,DUO Fei,ZHANG Jinchuan,et al.Performance and bearing capacity calculation method of concrete-filled double steel tubular composite stub columns under fire[J].Journal of Architecture and Civil Engineering,2024,41(01):128.[doi:10.19815/j.jace.2022.03101]
[7]巴光忠,郑欣欣,刘才玮,等.火灾后锈蚀混凝土梁抗弯性能试验研究[J].建筑科学与工程学报,2024,41(01):138.[doi:10.19815/j.jace.2022.04005]
 BA Guangzhong,ZHENG Xinxin,LIU Caiwei,et al.Experimental study on flexural performance of corroded reinforced concrete beams after fire exposure[J].Journal of Architecture and Civil Engineering,2024,41(01):138.[doi:10.19815/j.jace.2022.04005]
[8]陈 莎,刘永健,王 壮,等.钢桥表面相对湿度的边界条件计算方法[J].建筑科学与工程学报,2024,41(02):85.[doi:10.19815/j.jace.2024.03010]
 CHEN Sha,LIU Yongjian,WANG Zhuang,et al.Calculation methods for boundary conditions of relative humidity on steel bridge surface[J].Journal of Architecture and Civil Engineering,2024,41(01):85.[doi:10.19815/j.jace.2024.03010]
[9]李 刚,钟小春.寒区隧道围岩温度场分布特征及影响因素分析[J].建筑科学与工程学报,2024,41(02):143.[doi:10.19815/j.jace.2022.08039]
 LI Gang,ZHONG Xiaochun.Temperature field distribution characteristics in cold region tunnels and surrounding rock and analysis of influencing factors[J].Journal of Architecture and Civil Engineering,2024,41(01):143.[doi:10.19815/j.jace.2022.08039]

备注/Memo

备注/Memo:
收稿日期:2011-11-07
基金项目:江苏省交通科学研究计划项目(09Y11)
作者简介:陈 扬(1984-),女,江苏泰州人,工学硕士,E-mail:alice-cy@163.com。
更新日期/Last Update: 2012-03-20