[1]尚守平,曹 勇,崔向龙.新型三维隔震礅振动台试验与数值分析[J].建筑科学与工程学报,2018,35(02):30-37.
 SHANG Shou-ping,CAO Yong,CUI Xiang-long.New Three-dimension Isolation Pier Vertical Vibration Table Test and Numerical Analysis[J].Journal of Architecture and Civil Engineering,2018,35(02):30-37.
点击复制

新型三维隔震礅振动台试验与数值分析(PDF)
分享到:

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

卷:
35卷
期数:
2018年02期
页码:
30-37
栏目:
出版日期:
2018-03-30

文章信息/Info

Title:
New Three-dimension Isolation Pier Vertical Vibration Table Test and Numerical Analysis
作者:
尚守平曹 勇崔向龙
湖南大学土木工程学院
Author(s):
SHANG Shou-ping, CAO Yong, CUI Xiang-long
College of Civil Engineering, Hunan University
关键词:
三维隔震礅振动台试验隔震效果内力分析竖向地震
Keywords:
three-dimension isolation pier vibration table test vibration isolation effect analysis of internal force vertical seismic
分类号:
-
DOI:
-
文献标志码:
A
摘要:
研究了一种以竖向圆柱螺旋压缩弹簧为隔震单元的新型三维隔震礅,介绍了隔震礅的构造和工作原理,通过静力试验确定三维隔震礅的竖向以及水平向刚度,在此基础上通过振动台试验研究了这种三维隔震礅的隔震效果。为定性研究三维隔震礅,采用VB编制计算程序对三维隔震礅的隔震性能进行数值分析,在加速度时程分析的基础上对单向与双向地震波作用下的梁端内力进行分析。振动台试验结果表明:三维隔震礅竖向以及水平向隔震系数均低于0.4,证明三维隔震礅具备良好的隔振性能。数值分析结果表明:在单向地震波作用下,隔震礅隔震系数低于0.4,双向地震波作用下,隔震礅隔震系数均低于0.6,证明三维隔震礅具有优秀的隔震效果。内力分析结果表明:竖向地震作用不可忽略。由此可知这种三维隔震礅具备良好的隔震效果,该新型三维隔震礅构造简易、效果良好,适于广大农村地区推广。
Abstract:
A new kind of three-dimension isolation pier in the unit of vertical cylinder helix compression spring was studied. The structure and the operation principle of the isolation pier were introduced. The vertical and horizontal rigidities of the three-dimension isolation pier were determined through static test, and the three-dimension pier’s isolation effect was studied by vibrating table test. What’s more, the VB computer program was used to do the numerical analysis for the qualitative research of the three-dimension pier. On the basis of the acceleration time-history analysis, the internal forces of the beam end under the unidirectional and bidirectional seismic waves were analyzed. The results of vibrating table test show that three-dimensional isolation pier’s horizontal and vertical isolation coefficients are less than 0.4, proving that the three-dimension isolation has a good vibration isolation effect. The results of numerical analysis show that the three-dimension isolation pier’s isolation coefficient is less than 0.4 under unidirectional seismic wave, while its isolation coefficient is less than 0.6 under bidirectional seismic wave, which indicates that the three-dimension pier has a good isolation effect. Meanwhile, the results of internal force analysis show that the vertical seismic action’s effect should not be neglected. With simple structure as well as good effects, this new three-dimension isolation pier is suitable for the rural areas.

参考文献/References:

相似文献/References:

[1]丁 陶,肖建庄.基于振动台试验的预制再生混凝土框架后浇边节点分析[J].建筑科学与工程学报,2013,30(03):78.
 DING Tao,XIAO Jian-zhuang.Analysis of Cast-in-situ Exterior Joints of Precast Recycled Aggregate Concrete Frame by Shaking Table Tests[J].Journal of Architecture and Civil Engineering,2013,30(02):78.
[2]申彦利,谷少康.钢筋混凝土空心矩形桥墩振动台试验[J].建筑科学与工程学报,2018,35(05):128.
 SHEN Yan-li,GU Shao-kang.Shake Table Test for Reinforced Concrete Hollow Rectangular Pier[J].Journal of Architecture and Civil Engineering,2018,35(02):128.

备注/Memo

备注/Memo:
更新日期/Last Update: 2018-04-04