Abstract:
Ultimate bearing capacity of single angle struts with one-sided bolt connection was studied by combining with the finite element simulation according to results of strut tests with 70 angles. The relationship between failure mode and slenderness ratio was discussed. The construction measures to increasing bearing capacity of this kind of members were also proposed. Based on the comparison of several relevant codes, revising suggestions for calculation formula of strut stability in Technical Regulation of Design for Tower and Pole Structures of Overhead Transmission Line(DL/T 5154—2002)were put forward. The analytical results show that failure of members with low slenderness ratio tends to cause local buckling, while failure of members with high slenderness ratio will cause flexural buckling. It is also pointed that different formulas for calculating equivalent slenderness ratio should be adopted respectively for members buckling towards parallel axis and those towards minor axis. Research results can provide theoretical basis for design of steel towers in the future.

References:

[1] DL/T 5154-2002,架空送电线路杆塔结构设计技术规定[S]. DL/T 5154-2002,Technical Regulation of Design for Tower and Pole Structures of Overhead Transmission Line[S].
[2]GB 50017-2003,钢结构设计规范[S]. GB 50017-2003,Code for Design of Steel Structures[S].
[3]ASCE 10-97,Design of Latticed Steel Transmission Structures[S].
[4]BS 5950-1:2000,Structural Use of Steelwork in Building.Code of Practice for Design.Rolled and Welded Sections[S].
[5]ECCS,European Recommendations for Steel Construction[S].
[6]EN 1993-1-1:2005,Eurocode 3.Design of Steel Structures.Part 1-1:General Rules and Rules for Buildings[S].
[7]DIN 18800,Structural Steelwork.Part 2:Analysis of Safety Against Buckling of Linear Members and Frames[S].
[8]ECCS Committee 8,Manual on Stability of Steel Structures[S].
[9]TEMPLE M C,SAKALA S S.Single Angle Compression Members Welded by One Leg to a Gusset Plate:Experimental Study[J].Can J Civ Eng,1998,25(3):569-584.
[10]陈绍蕃.单边连接单角钢压杆的计算与构造[J].建筑科学与工程学报,2008,25(2):72-78. CHEN Shao-fan.Calculation and Construction of Single-angle Steel Struts Connected by One Leg[J].Journal of Architecture and Civil Engineering,2008,25(2):72-78.
[11]郭秉山,彭 军,刘朝科.梁腹板削弱式刚性钢框架抗震性能研究[J].西安科技大学学报,2007,27(3):364-367. GUO Bing-shan,PENG Jun,LIU Chao-ke.Anti-seismic Performance Testing of New Beam-to-column Connections in Steel Frames[J].Journal of Xi'an University of Science and Technology,2007,27(3):364-367.
[12]孙巍巍,任志浩,孟少平.交错孔洞平板螺栓连接有限元研究[J].西安建筑科技大学学报:自然科学版,2008,40(2):196-200. SUN Wei-wei,REN Zhi-hao,MENG Shao-ping.Finite Element Investigation on Steel Plate Bolted Tension Members with Staggered Holes[J].Journal of Xi'an University of Architecture & Technology:Natural Science Edition,2008,40(2):196-200.
[13]李启才,顾 强.抗滑移系数对框架中钢梁高强度螺栓拼接性能的影响研究[J].西安科技大学学报,2007,27(1):43-48. LI Qi-cai,GU Qiang.Effect of Slipping Coefficient on Splicing of High-strength Bolts on Steel Beam in Moment-resisting Frame[J].Journal ofXi'an University of Science and Technology,2007,27(1):43-48.
[14]康强文,童根树.单肢连接的单角钢压杆承载力分析[J].钢结构,2006,21(2):7-11. KANG Qiang-wen,TONG Gen-shu.Load-carrying Capacity of Single Angle Struts Connected with One Leg[J].Steel Construction,2006,21(2):7-11.
[15]刘沪昌,唐国安.轴心受压热轧等边角钢肢边缘局部屈曲稳定计算方法的探讨[J].电力建设,2007,28(9):1-4. LIU Hu-chang,TANG Guo-an.Computation Methodology of Buckling Stability of Hot Rolled Steel Angle Edge Under Axial Compression[J].Electric Power Construction,2007,28(9):1-4.

Memo

Memo:
-
Last Update: 2009-12-20