Mechanical Property Study on Split Joint Concrete Composite Slab
作者:
何庆锋1,2,杨凯华1
(1. 湖南大学 土木工程学院,湖南 长沙 410082; 2. 湖南大学 工程结构损伤诊断湖南省重点实验室,湖南 长沙 410082)
Author(s):
HE Qing-feng1,2, YANG Kai-hua1
(1. College of Civil Engineering, Hunan University, Changsha 410082, Hunan, China; 2. Hunan Provincial Key Laboratory on Damage Diagnosis for Engineering Structures, Hunan University, Changsha 410082, Hunan, China)
关键词:
钢筋混凝土叠合板 分离式拼缝 马镫钢筋 受力性能 附加钢筋
Keywords:
reinforced concrete composite slab split joint stirrup reinforcement mechanical property additional reinforcement
分类号:
TU375.2
DOI:
10.19815/j.jace.2020.03042
文献标志码:
A
摘要:
为研究采用马镫钢筋作为抗剪拉结钢筋的分离式拼缝混凝土叠合板的受力性能,通过3块简支板的静力加载试验,对其在不同马镫钢筋布置下的荷载-挠度曲线、承载能力、变形性能进行了研究,并分析了其裂缝成因、拼缝处受力机理,推导了其开裂荷载的计算式。结果表明:规范分离式拼缝叠合板的荷载-挠度曲线发展趋势为三折线形,其开裂荷载计算与普通叠合板计算有所区别; 试件拼缝处易产生沿着叠合面的撕裂破坏,其附加钢筋容易发生局部滑移或者锚固失效; 试件屈服荷载受附加钢筋的黏结滑移影响有一定的降低,其极限承载力取决于拼缝处现浇混凝土与预制板的拉结强度; 试件拼缝处裂缝数目与宽度和马镫钢筋有关,合理改变马镫钢筋布置能够有效减少裂缝数目及宽度; 试件屈服前变形呈现整体弯曲,屈服后变形主要集中在拼缝处,最终试件均出现了混凝土压碎现象,其破坏形态呈现二折线形; 根据相关规范,针对附加钢筋滑移问题可通过锚固弯钩、加长钢筋长度、抬高钢筋位置等措施进行改进。
Abstract:
In order to study the mechanical properties of split joint reinforced concrete composite slab with stirrup as shear tie reinforcement, the load-deflection curve, bearing capacity and deformation performance of three simply supported slabs under different stirrup arrangements were studied. The causes of the cracks, the mechanical mechanism of the joints and the calculation formula of the cracking load were also analyzed. The results show that the development trend of load-deflection curve of standard split joint composite slab is trilinear, and the calculation of cracking load is different from that of common composite slab. The joint of the specimen is prone to tear along the composite plane, and the additional reinforcement is easy to slip or anchor failure. The yield load of the specimen is affected by the bond slip of the additional reinforcement, and its ultimate bearing capacity depends on the tensile strength between the cast-in-place concrete and the precast slab at the joint. The number and width of cracks are related to stirrup bars. Reasonable arrangement of stirrup bars can effectively reduce the number and width of cracks. Before yielding, the deformation of specimens present overall bending, and after yielding, the deformation is mainly concentrated in the joint. The concrete crushing phenomenon appears in all specimens, and the failure mode is close to two fold linear. According to the relevant codes, the problem of additional reinforcement sliding can be improved by anchoring hooks, lengthening the length and raising the position of reinforcement.

参考文献/References:

[1] 曾 敏,胡 翔,陈培良,等.预应力混凝土叠合板试验及计算方法研究[J].住宅科技,2016,36(4):13-17.
ZENG Min,HU Xiang,CHEN Pei-liang,et al.Study on Test and Calculation Method of Prestressed Concrete Composite Slab[J].Housing Science,2016,36(4):13-17.
[2]JGJ 1—2014,装配式混凝土结构技术规程[S].
JGJ 1—2014,Technical Specification for Precast Concrete Structures[S].
[3]余泳涛,赵 勇,高志强.单缝密拼钢筋混凝土叠合板受弯性能试验研究[J].建筑结构学报,2019,40(4):29-37.
YU Yong-tao,ZHAO Yong,GAO Zhi-qiang.Experimental Research on Flexural Behavior of Reinforced Concrete Composite Slab Connected Without Gap[J].Journal of Building Structures,2019,40(4):29-37.
[4]LUKASZEWSKA E,FRAGIACOMO M,JOHNSSON H.Laboratory Tests and Numerical Analyses of Prefabricated Timber-concrete Composite Floors[J].Journal of Structural Engineering,2015,136(1):46-55.
[5]BANK L,OLIVA M,RUSSELL J,et al.Double-layer Prefabricated FRP Grids for Rapid Bridge Deck Construction:Case Study[J].Journal of Composites for Construction,2006,10(3):204-212.
[6]NAM J H,YOON S J,MOON H D,et al.Development of FRP-concrete Composite Bridge Deck in Korea State-of-the-art Review[J].Key Engineering Materials,2006,236-328:1705-1708.
[7]SAKKA Z,GILBERT R I.Structural Behavior of Two-way Slabs Reinforced with Low-ductility WWF[J].Journal of Structural Engineering,2017,143(12):04017166.
[8]QUINTAS V.Two Main Methods for Yield Line Analysis of Slabs[J].Journal of Engineering Mechanics,2003,129(2):223-231.
[9]CHUNG J H,JUNG H S,BAE B I,et al.Two-way Flexural Behavior of Donut-type Voided Slabs[J].International Journal of Concrete Structures and Materials,2018,12(1):1-13.
[10]FALL D,SHU J P,REMPLING R,et al.Two-way Slabs:Experimental Investigation of Load Redistributions in Steel Fibre Reinforced Concrete[J].Engineering Structures,2014,80:61-74.
[11]聂建国,陈必磊,陈 戈,等.钢筋混凝土叠合板的试验研究[J].工业建筑,2003,33(12):43-46,33.
NIE Jian-guo,CHEN Bi-lei,CHEN Ge,et al.Experimental Study on Shear Behavior of R.C.Laminated Slabs[J].Industrial Construction,2003,33(12):43-46,33.
[12]侯和涛,陈 磊,程佑东,等.预制混凝土叠合板钢筋黏结性能的研究[J].混凝土与水泥制品,2016(2):63-68.
HOU He-tao,CHEN Lei,CHENG You-dong,et al.Study on the Bond Behavior of Steel Bars in Precast Concrete Composite Slabs[J].China Concrete and Cement Products,2016(2):63-68.
[13]叶献国,华和贵,徐天爽,等.叠合板拼接构造的试验研究[J].工业建筑,2010,40(1):59-63.
YE Xian-guo,HUA He-gui,XU Tian-shuang,et al.Experimental Study on Connections of Superimposed Slabs[J].Industrial Construction,2010,40(1):59-63.
[14]刘运林,叶献国,种 迅,等.端拼缝叠合楼板受力性能试验研究[J].建筑结构,2015,45(4):85-89.
LIU Yun-lin,YE Xian-guo,CHONG Xun,et al.Experimental Study on Mechanical Performance of Composite Slab with End Joints[J].Building Structure,2015,45(4):85-89.
[15]黄 璐.PK混凝土拼接叠合板受力性能试验研究与分析[D].长沙:湖南大学,2012.
HUANG Lu.Study of Load-bearing Properties of PK Non-prestressed Composite Slab[D].Changsha:Hunan University,2012.
[16]DBJ 43/T 301—2013,混凝土叠合楼盖装配整体式建筑技术规程[S].
DBJ 43/T 301—2013,Technical Specification for Concrete Composite Floor Assembly Integrated Building[S].
[17]GB 50010—2010,混凝土结构设计规范[S].
GB 50010—2010,Code for Design of Concrete Structures[S].
[18]GB/T 50152—2012,混凝土结构试验方法标准[S].
GB/T 50152—2012,Standard for Test Method of Concrete Structures[S].
[19]何庆锋,杨凯华.密拼叠合板接缝构造与抗弯受力性能试验研究[J].西安建筑科技大学学报:自然科学版,2020,52(5):684-692.
HE Qing-feng,YANG Kai-hua.Study on the Joint Structure and Bending Resistance of Composite Slab Connected Without Gap[J].Journal of Xi'an University of Architecture & Technology:Natural Science Edition,2020,52(5):684-692.
[20]沈蒲生,梁兴文.混凝土结构设计原理[M].4版.北京:高等教育出版社,2012.
SHEN Pu-sheng,LIANG Xing-wen.Design Theory for Concrete Structures[M].4th ed.Beijing:Higher Education Press,2012.
[21]过镇海,时旭东.钢筋混凝土原理和分析[M].北京:清华大学出版社,2003.
GUO Zhen-gai,SHI Xu-dong.Reinforced Concrete Theory and Analyses[M].Beijing:Tsinghua University Press,2003.
[22]刘运林.双向叠合楼板拼缝处受力机理试验研究与数值模拟[D].合肥:合肥工业大学,2014.
LIU Yun-lin.Experimental Research and Numerical Analysis on Stress Mechanism in the Joint of Two-way Superimposed Slab[D].Hefei:Hefei University of Technology,2014.
[23]翁传阳.含附加钢筋的混凝土叠合板试验研究[D].合肥:安徽建筑大学,2014.
WENG Chuan-yang.Experimental Study About Concrete Composite Slabs with Additional Bars[D].Hefei:Anhui Jianzhu University,2014.
[24]张麟斌.装配式混凝土节点形式及梁柱结构抗倒塌性能试验研究[D].长沙:湖南大学,2019.
ZHANG Lin-bin.Experimental Study on Forms of Assembled Concrete Joints and Collapse Resistance of Beam-column Structures[D].Changsha:Hunan University,2019.
[25]付 伟.新型叠合板拼缝构造静载试验研究[D].长沙:湖南大学,2017.
FU Wei.The Joint of New Type Composite Slab Performance Under Static Test[D].Changsha:Hunan University,2017.
[26]赵志方,赵国藩,刘 健,等.新老混凝土粘结抗拉性能的试验研究[J].建筑结构学报,2001,22(2):51-56.
ZHAO Zhi-fang,ZHAO Guo-fan,LIU Jian,et al.Experimental Study on Adhesive Tensile Performance of Young on Old Concrete[J].Journal of Building Structures,2001,22(2):51-56.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期:2020-08-03
基金项目:国家重点研发计划项目(2016YFC0701400)
作者简介:何庆锋(1979-),男,湖北黄冈人,高级工程师,工学博士,E-mail:sammyhqf@163.com。
更新日期/Last Update: 2021-05-20