|本期目录/Table of Contents|

[1]褚云朋,江天勇,陈雪琴,等.采用混合连接的冷弯薄壁型钢工字形拼合柱轴压性能试验研究[J].建筑科学与工程学报,2025,42(04):64-75.[doi:10.19815/j.jace.2023.10004]
 CHU Yunpeng,JIANG Tianyong,CHEN Xueqin,et al.Experimental study on axial compression properties of cold-formed thin-walled steel I-shaped column with hybrid connection[J].Journal of Architecture and Civil Engineering,2025,42(04):64-75.[doi:10.19815/j.jace.2023.10004]
点击复制

采用混合连接的冷弯薄壁型钢工字形拼合柱轴压性能试验研究(PDF)
分享到:

《建筑科学与工程学报》[ISSN:1673-2049/CN:61-1442/TU]

卷:
42卷
期数:
2025年04期
页码:
64-75
栏目:
建筑结构
出版日期:
2025-07-10

文章信息/Info

Title:
Experimental study on axial compression properties of cold-formed thin-walled steel I-shaped column with hybrid connection
文章编号:
1673-2049(2025)04-0064-12
作者:
褚云朋,江天勇,陈雪琴,伏金蓉,夏珲
(西南科技大学 土木工程与建筑学院,四川 绵阳 621010)
Author(s):
CHU Yunpeng, JIANG Tianyong, CHEN Xueqin, FU Jinrong, XIA Hui
(School of Civil Engineering and Architecture, Southwest University of Science and Technology, Mianyang 621010, Sichuan, China)
关键词:
冷弯薄壁型钢 混合连接 双肢开口拼合柱 试验研究 修正直接强度法
Keywords:
cold-formed thin-walled steel hybrid connection double-limb open-section column experimental study modified direct strength method
分类号:
TU392
DOI:
10.19815/j.jace.2023.10004
文献标志码:
A
摘要:
为分析连接方式对冷弯薄壁型钢双肢开口拼合工字形柱轴压力学性能的影响,对24根自攻螺钉与拉铆钉混合连接方式下的双肢开口拼合工字形柱开展试验研究,得到了试件的极限承载力、破坏模式、荷载-应变曲线及荷载-轴向位移曲线等,并将试验结果与纯自攻螺钉连接的双肢开口拼合工字形柱进行对比。结果表明:与纯自攻螺钉连接方式相比,两种混合连接方式的双肢开口拼合工字形短柱极限承载力分别提高了8.5%和8.6%,而中柱分别提高了18.1%和15.9%; 连接方式对拼合短柱与中柱的屈曲荷载影响较大,对短柱的极限承载力影响较大,对中柱的极限承载力影响则较小; 采用混合连接方式的拼合柱极限承载力普遍高于纯自攻螺钉连接的拼合柱,随连接件纵距增加,混合连接方式下的拼合柱极限承载力均逐步降低,但始终高于纯自攻螺钉连接的拼合柱,说明混合连接能有效提升拼合柱的稳定性; 根据试验结果对北美规范的直接强度法进行修正,为采用混合连接的双肢开口拼合柱的极限承载力计算提供参考。
Abstract:
In order to analyze the influence of connection mode on the axial compressive mechanical properties of cold-formed thin-walled steel double-limb open-ended assembled I-shaped columns, the experimental study on 24 double-limb open-ended assembled I-shaped columns under the mixed connection mode of self-tapping screws and rivets was carried out. The ultimate bearing capacity, failure mode, load-strain curve and load-axial displacement curve of the specimens were obtained, and the experimental results were compared with those of the double-limb open-ended assembled I-shaped columns connected by pure self-tapping screws. The results show that compared with the pure self-tapping screw connection method, the ultimate bearing capacity of the double-limb open-ended assembled I-shaped short columns of the two hybrid connection methods is increased by 8.5% and 8.6%, respectively, while the middle column is increased by 18.1% and 15.9%, respectively. The connection mode has a great influence on the buckling load of the short column and the middle column, and has a great influence on the ultimate bearing capacity of the short column, but has little influence on the ultimate bearing capacity of the middle column. The ultimate bearing capacity of the combined column with mixed connection is generally higher than that of the combined column with pure self-tapping screw connection. With the increase of the longitudinal distance of the connector, the ultimate bearing capacity of the combined column with mixed connection is gradually reduced, but it is always higher than that of the combined column with pure self-tapping screw connection, indicating that the mixed connection can effectively improve the stability of the combined column. According to the test results, the direct strength method of the North American code is modified to provide a reference for the calculation of the ultimate bearing capacity of the double-limb split column with hybrid connection.

参考文献/References:

[1] 徐吉民,幸坤涛,高向宇,等.锈损冷弯薄壁卷边槽钢短柱受压承载力试验研究[J].工程力学,2021,38(4):191-199,210.
XU Jimin, XING Kuntao, GAO Xiangyu, et al. Experimental investigation on compressive bearing capacity of cold-formed thin-walled lipped channel short columns with corrosion[J]. Engineering Mechanics, 2021, 38(4): 191-199, 210.
[2]冷弯薄壁型钢结构技术规范:GB 50018—2002[S].北京:中国标准出版社,2003.
Technical code of cold-formed thin-wall steel structures: GB 50018—2002[S]. Beijing: Standards Press of China, 2003.
[3]North American specification for the design of cold-formed steel structural members: AISI S100-2007[S]. Washington: American Institute of Steel Construction, 2007.
[4]STONE T A, LABOUBE R A. Behavior of cold-formed steel built-up I-sections[J]. Thin-walled Structures, 2005, 43(12): 1805-1817.
[5]刘慧颖.开口拼合冷弯薄壁型钢轴压短柱试验与理论研究[D].西安:长安大学,2010.
LIU Huiying. Experimental and theoretical study on split cold-formed thin-walled steel short columns under axial compression[D]. Xi'an: Chang'an University, 2010.
[6]李元齐,姚行友,沈祖炎,等.高强冷弯薄壁型钢抱合箱形截面受压构件承载力试验研究[J].建筑结构, 2011,41(6):36-41.
LI Yuanqi, YAO Xingyou, SHEN Zuyan, et al. Load-carrying capacity of 550 MPa high-strength cold-formed thin-walled steel built-up box section columns[J]. Building Structure, 2011, 41(6): 36-41.
[7]崔 瑶, 陈宇彤,宋世聪.冷弯薄壁型钢多肢拼合柱轴压承载力计算方法对比分析[J].建筑钢结构进展,2019,21(6):89-96.
CUI Yao, CHEN Yutong, SONG Shicong. Comparison analysis of calculation methods for axial compression capacity of cold-formed thin-walled steel columns with built-up sections[J]. Progress in Steel Building Structures, 2019, 21(6): 89-96.
[8]SANG L R, ZHOU T H, ZHANG L, et al. Local buckling in cold-formed steel built-up I-section columns: experiments, numerical validations and design considerations[J]. Structures, 2023, 47: 134-152.
[9]姚行友,李 潇.冷弯薄壁型钢拼合工字形截面柱畸变屈曲及相关屈曲轴压性能试验与直接强度法研究[J].建筑钢结构进展,2021,23(12):33-46.
YAO Xingyou, LI Xiao. Tests and direct strength method on the distortional buckling and interactive buckling of cold-formed thin-walled steel built-up I-section columns under axial compression[J]. Progress in Steel Building Structures, 2021, 23(12): 33-46.
[10]CHEN M H, FAN S G, LIU J J, et al. Design of stainless steel lipped channel columns subjected to distortional-global interactive buckling using the direct strength method[J]. Thin-walled Structures, 2022, 179: 109698.
[11]聂少锋,周天华,袁涛涛,等.冷弯薄壁型钢拼合箱形截面立柱轴压性能试验研究[J].土木建筑与环境工程,2012,34(4):46-52.
NIE Shaofeng, ZHOU Tianhua, YUAN Taotao, et al. Experimental analysis on behavior of cold-formed steel box built-up section columns under axial compression[J]. Journal of Civil, Architectural & Environmental Engineering, 2012, 34(4): 46-52.
[12]周天华, 聂少锋, 刘向斌.冷弯薄壁型钢开口三肢拼合立柱轴压性能试验研究[J].建筑结构学报,2012,33(3):22-29.
ZHOU Tianhua, NIE Shaofeng, LIU Xiangbin. Experimental study on cold-formed steel three limbs built-up section members under axial compression[J]. Journal of Building Structures, 2012, 33(3): 22-29.
[13]LU Y, ZHOU T H, LI W C, et al. Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns[J]. Thin-walled Structures, 2017, 112: 125-139.
[14]聂少锋,霍洋洋,周天华,等.冷弯薄壁型钢四肢拼合箱形柱偏压受力性能试验研究与数值分析[J].土木工程学报,2016,49(10):1-10,17.
NIE Shaofeng, HUO Yangyang, ZHOU Tianhua, et al. Experimental study and numerical analysis on cold-formed thin-walled quadruple-limb built-up box-section columns under eccentric compression[J]. China Civil Engineering Journal, 2016, 49(10): 1-10, 17.
[15]聂少锋,周天华,周绪红,等.双肢冷弯薄壁型钢拼合箱形柱受压试验研究与有限元分析[J].建筑结构学报,2017,38(10):10-20.
NIE Shaofeng, ZHOU Tianhua, ZHOU Xuhong, et al. Experimental study and numerical analysis on double limb cold-formed steel built-up closed section columns under compression[J]. Journal of Building Structures, 2017, 38(10): 10-20.
[16]聂少锋,周天华,周绪红,等.三肢冷弯薄壁型钢拼合双腔箱形柱受压性能试验研究与数值分析[J].东南大学学报(自然科学版),2019,49(1):25-33.
NIE Shaofeng, ZHOU Tianhua, ZHOU Xuhong, et al. Experimental study and numerical analysis on compressive behavior of three-limb built-up cold-formed steel columns with double box section[J]. Journal of Southeast University(Natural Science Edition), 2019, 49(1): 25-33.
[17]张兴春.冷弯薄壁型钢拼合工形截面轴压短柱基于“承载力单元” 的叠加法研究[D].西安:长安大学,2021.
ZHANG Xingchun. Research on superposition method “bearing capacity unit” for axial compression of cold-formed steel built-up I-section short column[D]. Xi'an: Chang'an University, 2021.
[18]SELVARAJ S, MADHAVAN M. Design of cold-formed steel built-up closed section columns using direct strength method[J]. Thin-walled Structures, 2022, 171: 108746.
[19]董事尔,杨 博,张爱荣.冷弯薄壁C型钢双肢闭合拼合柱的极限承载力研究[J].工业建筑,2022,52(11):175-180,174.
DONG Shier, YANG Bo, ZHANG Airong. Research on ultimate bearing capacity of cold-formed thin-walled C-section steel double-limbed closed built-up columns[J]. Industrial Construction, 2022, 52(11): 175-180, 174.
[20]金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2021[S].北京:中国标准出版社,2021.
Metallic materials — tensile testing: part 1: method of test at room temperature: GB/T 228.1—2021[S]. Beijing: Standards Press of China, 2021.
[21]路 延.冷弯薄壁型钢双肢开口拼合轴压柱失稳机理和承载力设计方法研究[D].西安:长安大学,2018.
LU Yan.Study on instability mechanism and bearing capacity design method of cold-formed thin-walled steel columns with two-limb split axial compression[D]. Xi'an: Chang'an University, 2018.

相似文献/References:

[1]高婷婷,周绪红,刘永健,等.采用GB 50018—2002计算壁厚小于2 mm的受弯构件承载力的适用性分析[J].建筑科学与工程学报,2013,30(04):91.
 GAO Ting-ting,ZHOU Xu-hong,LIU Yong-jian,et al.Applicability Analysis of Bear Capacity of Flexural Members with Thickness Less than 2 mm Calculated Using GB 50018—2002[J].Journal of Architecture and Civil Engineering,2013,30(04):91.
[2]石 宇,王身伟,刘永健.冷弯薄壁型钢单颗自攻螺钉抗剪连接性能研究[J].建筑科学与工程学报,2014,31(02):57.
[3]石宇,周绪红,刘永健.冷弯薄壁卷边槽钢偏心受压构件承载力计算的折减强度法[J].建筑科学与工程学报,2011,28(03):40.
 SHI Yu,ZHOU Xu-hong,LIU Yong-jian.Strength-reduction Method for Load-carrying Capacity of Cold-formed Thin-walled Lipped Channel Members Under Eccentric Compression[J].Journal of Architecture and Civil Engineering,2011,28(04):40.
[4]刘向斌,周天华,聂少锋,等.冷弯薄壁型钢开口三肢拼合立柱轴压性能有限元分析[J].建筑科学与工程学报,2011,28(03):119.
 LIU Xiang-bin,ZHOU Tian-hua,NIE Shao-feng,et al.Finite Element Analysis of Cold-formed Thin-walled Steel Three Open Limbs Built-up Columns Under Axial Compression[J].Journal of Architecture and Civil Engineering,2011,28(04):119.
[5]聂少锋,周天华,熊智刚,等.冷弯薄壁型钢开洞组合墙体抗剪性能研究[J].建筑科学与工程学报,2012,29(01):101.
 NIE Shao-feng,ZHOU Tian-hua,XIONG Zhi-gang,et al.Research on Shear Resistance Behavior of Cold-formed Thin-walled Steel Composite Walls with Opening[J].Journal of Architecture and Civil Engineering,2012,29(04):101.
[6]刘向斌,周天华,何鑫,等.冷弯薄壁型钢住宅结构整体扭转效应分析[J].建筑科学与工程学报,2012,29(02):83.
 LIU Xiang-bin,ZHOU Tian-hua,HE Xin,et al.Analysis of Torsional Effect of Cold-formed Thin-walled Steel Residence Structure[J].Journal of Architecture and Civil Engineering,2012,29(04):83.
[7]周绪红,李喆,刘永健,等.冷弯薄壁型钢拼合截面柱轴压承载力计算[J].建筑科学与工程学报,2012,29(04):1.
 ZHOU Xu-hong,LI Zhe,LIU Yong-jian,et al.Calculation Method for Bearing Capacity of Cold-formed Steel Built-up Columns Under Axial Compression[J].Journal of Architecture and Civil Engineering,2012,29(04):1.
[8]刘晶波,陈鸣,刘祥庆,等.低层冷弯薄壁型钢结构住宅整体性能分析[J].建筑科学与工程学报,2008,25(04):6.
 LIU Jing-bo,CHEN Ming,LIU Xiang-qing,et al.Integral Behavior Analysis of Cold-formed Thin-walled Steel Framing System of Low-rise Residential Buildings[J].Journal of Architecture and Civil Engineering,2008,25(04):6.
[9]周绪红,李艳敏,石宇,等.竖向荷载作用下冷弯薄壁型钢墙架柱的承载力[J].建筑科学与工程学报,2006,23(03):7.
 ZHOU Xu-hong,LI Yan-min,SHI Yu,et al.Bearing Capacity of Cold-Formed Thin-WalledSteel Wall Stud Under Vertical Load[J].Journal of Architecture and Civil Engineering,2006,23(04):7.
[10]管 宇,周绪红,石 宇,等.多层冷弯薄壁型钢住宅体系动力时程分析[J].建筑科学与工程学报,2018,35(05):142.
 GUAN Yu,ZHOU Xu-hong,SHI Yu,et al.Dynamic Time History Analysis for Mid-rise Cold-formed Thin-walled Steel Residential Building System[J].Journal of Architecture and Civil Engineering,2018,35(04):142.

备注/Memo

备注/Memo:
收稿日期:2023-10-25
基金项目:国家自然科学基金项目(52268029); 四川省自然科学基金项目(2023NSFSC0381)
作者简介:褚云朋(1979-),男,工学博士,教授,E-mail:chuyunpeng@swust.edu.cn。
Author resume: CHU Yunpeng(1979-), male, PhD, professor, E-mail: chuyunpeng@swust.edu.cn.
更新日期/Last Update: 2025-07-10